Herunterladen Inhalt Inhalt Diese Seite drucken

Mechanical Installation Conditions Of Force Transducers; Precautions To Take During Assembly - Tecsis F1301 Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Betriebsanleitung/Operating manual
F1301/F13C1
6

Mechanical installation conditions of force transducers

6.1

Precautions to take during assembly

Force measuring equipment is extremely sensitive and must be
handled carefully.
Attention must be paid to the installation position and therefore the load
direction when the force transducers are being installed.
Torsional moments, off-centre loads and lateral loads cause
measuring errors and can permanently damage the transducers.
Care must therefore be taken to keep the transducer free of lateral
loads and torsion during assembly (e.g. when tightening the lock
nuts).
Overloading must be prevented at all times.
The output signal (2mV/V, 4...20mA, 0...10V) is noted on the name
plate (Fig. 3). The connection assignments are also noted on the
name plate and can also be found in the section entitled "Electrical
connection". The polarity must be correct at all times.
Type
S#
UB+
0V/S-
S+
UR+, UR- Pin assignment – power supply Relay
24
Model
Signal
Power suply
Product no.
Pin assignment – power supply +
Pin assignment – power supply - / signal -
Pin assignment – signal +
BD_BE 982
Fig. 1 label
www.tecsis.de