16. TECHNICAL DATA

Mains voltage:
230 V ~ + 10/-10%/50 Hz
Class of protection:
control unit - class Il
motion detectors - class Il
siren - class Il
SS/alarm switch class I
Average power consumption
per system component:
approx. 3 Watt
Transmission output:
5 mW
Frequency range:
95 kHz - 146.0 kHz
Transmission channel:
3 frequencies occupied
alternately (frequency-diversity)
Modulation mode:
FSK
Coding:
digital
Channel occupation:
time derived system
Average duration of tamper recognition:
approx. 120 sec.
Phase allocation:
continued operation independent
of phases and without phase coupler
Seite 37
Max. to be connected to the control unit:
4 detectors
Max. 4 alarm switches switching socket in
any combination
1 siren
One parallel control unit or
1 telephone dialling device
Motion detectors:
passive infra-red (PIR)
Detection area:
horizontally max. 140°
vertically 8° sym. (type I), +3°/-10° (type II)
distance approx. 7 m
Switching socket/alarm switch:
Switching capacity 1000 Watt
halogen lamps max. 500 Watt
switch-on time approx. 15 sec -10 min (can
be pre-selected)
(alarm switch only)
Siren:
alarm tone 100 dB, duration 30 sec.,
break 30 sec.,
10 minutes periodically
Display functions:
light-emitting diode (LED)
Tamper protection:
via interrogation system with feedback
channel
Dimensions of a system component (mm):
134 (H) x 80 (W) x 64 (D without plug)
Duration of initial operation:
approx. 15 minutes
Temperature range for operation: 0°-40°C