Assembly instruction
CAE3000-IP
ARGOS
2
Wall mounting
The dimensions of the wall cutout for the flush-mount installation are:
125 x 300 x 38 mm (H x W x D).
1
►Take the ARGOS front-door
station out of the packaging.
►Loosen the locking screws at
the bottom (1) of the ARGOS
frontdoor station.
2
►Push the front panel carefully
upwards (2).
►Remove the front panel from the
flush-mount box (3).
►Put down the front panel on a
►soft and clean surface.
1
2
ARGOS
1
Preparations
Carefully observe the procedure for the installation of the ARGOS front-door
station to avoid any damages and malfunctions.
1.1
Scope of delivery
• Carus ARGOS IP video front-door station (CAE3000-IP-015x)
• installation kit with screws, dowels and sealings
• allen key (wrench size 2.0) to interlock the front panel
• ethernet cabel
• 3 RFID cards (green, red and grey)
• wall housing for surface-mount and flush-mount
• assembly instruction
1.2
Installation site
• can be used indoors and outdoors (degree of protection IP65, -20 °C to +60 °C
ambient temperature)
1,57 m
ARGOS
3
►Place the sealing plug for the
cable in the required opening in
the flush-mount box (4).
►Seal the cable gland, which is
not used, with the enclosed
1
sealing plug (5).
Use the sealing plugs enclosed in the
delivery. There are no warranty claims in case of
an improper installation.
4
►Mark the drilling holes by using
the the flush-mount box as
drilling template.
►Guide the cable throught the
sealing plug (6).
►Use the material enclosed in the
delivery to install the device.
Ensure that the flush-mount box is installed ver-
tically. Therefore use the integrated bubble level.
The orientation of the device cannot be orrected
later.
5
Installation
5.1
Flush-mount installation in cavity
wall
The inner drilling holes are sealed with a sealing
plug (7) ex works.
ARGOS
1.3
Interfaces
The parts described in the assembly instruction are either part of the delivery or
available from our list of accessories. All connections are located on the circuit
board which is installed on the rear side of the device.
1.3.1 Ethernet, Power-over-Ethernet (PoE)
Establish an ethernet connection via the ethernet socket.
For power supply via ethernet (PoE) use a PoE-enabled switch or a PoE injector.
1.3.2 FEW1000 ethernet 2-wire IP converter (optional accessory)
Connect both ends of the 2-wire cable to the 2-wire socket. Ensure an adequate
line diameter in case of large distances.
ARGOS
Fluh-mount installation in solid
5.2
walls
2
5.3
Surface-mount
• Always use the inner drilling holes to fix the-
flush-mount box in case of surface-mount.
• To mark the inner drilling holes (8) you
canpuncture the sealing plugs with a small-
screwdriver.
• The screws need to be screwed through the-
sealing plugs. Thus, a selaing is guaranteed.
6
►Establish the required connecti-
on (9) (see chapter 1.3).
ARGOS
1.3.3 Connections and screw terminals
For positioning and connection pin assignment please see the following image:
GND
Trig. 2
Trig. 1
+12 V
2-wire pair
GND
Trig. 2
NC2
push button
Trig. 1
+12 V
NO2
NC2
2-wire power LED
NO2
COM 2
COM 2
2-wire signal LED
NC1
NC1
NO1
COM 1
NO1
slot for
+
-
2-wire option
COM 1
alternative power supply
polarity-free
(AC 20 V~ - 40 V~ or
DC 24 V - 56 V)
local power supply
slot for RFID
(12 V, 1 A, DC voltage)
(optional)
ethernet socket
Switching input with 4 pins:
The ARGOS front-door station is equipped with 2 switching inputs which are
routed potential-free via optocoupler.
At the screw terminal with 4 pins there is an output voltage of +12 V. Thus, an
external mains adapter is not necessary.
Relay 1 and relay 2 (with 3 pins):
There are 2 separated relay outputs available, both are designed as changeover
switch.
Local power supply (with 2 pins):
For power supply via mains adapter (12 V, 2 A, DC voltage). Ensure the correct
polarity.
The local power supply via mains adapter has priority over PoE supply.
Alternative power supply over wall wart adapter (AC 20 V~ - 40 V~ or DC 24 V - 56 V).
The connection is polarity-free.
ARGOS
7
►Hang the front panel into the
guidance points of the flush-
mount box (10).
►Push the front panel downwards
carefully (11).
2
1
8
►Secure the front panel by using
the locking screws (12).
3 Configuration
Product information and instruction manual are available in our download center
on our homepage www.carus-concepts.com.
CARAUS CONCEPTS
Designmanufaktur Adelheid
CARUS is a brand of
Adelheid 41 | 78098 Triberg
TCS TürControlSysteme AG
Telefon
Fax
E-Mail
11/2015
+
-
07722 91 77-22
07722 91 77-18
carus@tcs-germany.de

Werbung

loading

Diese Anleitung auch für:

Cae3000-ip