Changing cartridge
For a safe cartridge change, unplug the tool or turn the station off before following these guidelines:
1. Removing
Loosen the screw and remove the cartridge.
Use a flat pliers if still hot.
3. Aligning
Alignment
Align the tip of the cartridge. Use a flat pliers
for a correct tip alignment.
Do not over-tighten the cartridge.
Compatible cartridges
CP station works with C120 cartridge range. Find the model that best suits your soldering needs
in www.jbctools.com
C120-004
C120-005
1,5mm
ø0,7
5mm
6
2. Inserting
Mark
Important: Insert the cartridge as far as
the mark for a correct connection.
4. Fixing
Important: Tighten the screw again being
careful not to over-tighten. This is necessary
for the tool to function.
C120-001
C120-009
C120-010
C120-009
C120-010
ø 0,2

USB Connector

Download the latest software from our website to improve your soldering station.
JBC Updater
www.jbctools.com/software.html
Update the station software via USB connection:
Cable USB AB
JBC Manager
www.jbctools.com/manager.html
Manage and monitor as many stations as your PC can handle by using the JBC Manager. You can
export data to another PC.
Cable
USB AB
USB
Hub
w w w.jbctools.com
JBC
Updater
any JBC
station
Manager Settings
Change settings for a
group of JBC stations at
JBC
the same time.
Manager
Register Settings
Create graphs of the
soldering process in real
time with power and
temperature data.
7