Safety guidelines

Electrical connection
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Installation and operation
-
-
-
8
Lunaqua 2002 Exp.p65
GB
Operating instructions
For your own safety, contact an electrician if you have any questions or
problems!
Electrical installations near garden ponds and swimming pools must comply
with international and national installation guidelines.
The safety transformer must be supplied with a measured current not greater
than 30mA via a fault current protection switch (FI or RCD).
The pond light must only be operated with the safety transformer with which it
is supplied, in accordance with VDE 0551 IEC-742 / EN 60742.
The electrical data of the supply grid must correspond to the data on the type
label of the safety transformer.
The wattage of the installed lamp must not exceed the wattage of the transformer
as indicated on the type label.
The transformer is designed for use in the open and for an ambient temperature
of -10°C to + 25°C. Do not expose the transformer to direct sunlight.
The pond light is designed for use in pond water within a temperature range of
+4°C to +35°C.
Never use a halogen lamp with a wattage less than 35W with the Lunaqua 2002/
35, since the halogen lamp caps have different dimensions which can lead to
problems with the contact.
Do not use the pond light if the connecting cables, safety transformer or pond
light appear to be defective!
Keep the connecting points dry!
Do not carry or pull the pond light or safety transformer by their connecting
cables!
Never open the casing of the pond light unless expressly directed to do so in the
instructions.
The Lunaqua 2002 pond light is designed for use only with 12V low voltage.
There is danger to life if it is connected to 230V!
Always disconnect the plugs of all devices that are in the water and of the pond
light before you carry out any work on the pond light!
The distance between the transformer and the edge of the pond must be at least
2 m. Position the transformer so that it won't be flooded!
Before placing the pond light in the pond, check that there is a watertight seal
between the lamp casing and the cover.