Herunterladen Inhalt Inhalt Diese Seite drucken

UTE Electronic Smart PDU SP4120200 Anleitung Seite 51

Inhaltsverzeichnis

Werbung

Spezifikationen
port {port_num} w atchdog bootretries show
portsensor
portsensor {port_num} {energy_sensor} value
show
snmp
snmp port set {ip_port}
snmp port show
snmp snmpget enabled set {off=0|on=1}
snmp snmpget enabled show
snmp snmpset enabled set {off=0|on=1}
snmp snmpset enabled show
snmp snmpv2 enabled set {off=0|on=1}
snmp snmpv2 enabled show
snmp snmpv2 public set "<text>"
snmp snmpv2 public show
snmp snmpv2 private set "<text>"
snmp snmpv2 private show
snmp snmpv3 enabled set {off=0|on=1}
snmp snmpv3 enabled show
snmp snmpv3 username set "<text>"
snmp snmpv3 username show
snmp snmpv3 authalg set {none=0|md5=1|sha1=2|
sha256=3|sha384=4|sha512=5}
snmp snmpv3 authalg show
snmp snmpv3 privalg set {no=0|des=1|3des=2|
aes128=3|aes192=4|aes256=5|aes192*=6|
aes256*=7}
snmp snmpv3 privalg show
snmp snmpv3 authpassw d set "{passw d}"
snmp snmpv3 privpassw d set "{passw d}"
snmp trap type set {none=0|v1=1|v2=2|v3=3}
snmp trap type show
snmp trap receiver {trap_num} set "{dns_name}" sets address and port of SNMP trap receiver
snmp trap receiver {trap_num} show
syslog
syslog enabled set {off=0|on=1}
syslog enabled show
syslog server set "{dns_name}"
syslog server show
system
system restart
system fabsettings
system bootloader
system flushdns
vt100
vt100 echo set {off=0|on=1}
vt100 echo show
vt100 reset
Notes
1. command can be entered on any level
2. the output may show 2 lines - the 1st line shows the actual state, the 2nd line the
status after reboot
3. the output may show several lines
51
Smart PDU SP4120200 / SP7120200
how s port w atchdog retry boot timeout
enters cmd group "portsensor"
show s energy sensor of given port
enters cmd group "snmp"
sets SNMP UDP port
show s SNMP UDP port
enables SNMP GET cmds on/off
show if SNMP GET cmds are enabled
enables SNMP SET cmds on/off
show if SNMP SET cmds are enabled
enables SNMP v2 on/off
show if SNMP v2 is enabled
enables SNMP v3 on/off
show if SNMP v3 isenabled
sets SNMP v2 public cummnity
show s SNMP v2 public community
sets SNMP v2 private community
show s SNMP v2 private community
sets SNMP v3 username
show s SNMP v3 username
sets SNMP v3 authentication
show SNMP v3 authentication algorithm
sets SNMP v3 privacy algorithm
show SNMP v3 privacy algorithm
sets SNMP v3 authentication passw ord
sets SNMP v3 privacy passw ord
sets type of SNMP traps
show SNMP trap type
show address and port of SNMP trap receiver
enters cmd group "syslog"
enables syslog msgs on/off
show if syslog enabled
sets address of syslog server
show s address of syslog server
enters cmd group "system"
restarts device
restore fab settings and restart device
enters bootloader mode
flush DNS cache
enters cmd group "vt100"
sets console echo state
show s console echo state
resets terminal
© 2016 U.T.E. Electronic GmbH & Co. KG

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Smart pdu sp7120200

Inhaltsverzeichnis