Herunterladen Inhalt Inhalt Diese Seite drucken

UTE Electronic Smart PDU SP4120200 Anleitung Seite 50

Inhaltsverzeichnis

Werbung

Spezifikationen
linesensor
linesensor {lines_num} {energy_sensor} value
show
linesensor {lines_num} label set "{name}"
linesensor {lines_num} label show
linesensor {lines_num} messages set {off=0|
on=1}
linesensor {lines_num} messages show
linesensor {lines_num} maxval set <float>
linesensor {lines_num} maxval show
linesensor {lines_num} minval set <float>
linesensor {lines_num} minval show
linesensor {lines_num} hyst set <float>
linesensor {lines_num} hyst show
linesensor beeper set {off=0|on=1}
linesensor beeper show
port
port {port_num} state set {off=0|on=1}
port {port_num} state show
port {port_num} reset
port {port_num} toggle
port {port_num} batch set {off=0|on=1} w ait
{num_secs} {off=0|on=1}
port {port_num} batch cancel
port {port_num} label set "{name}"
port {port_num} label show
port {port_num} tw inport set {off=0|on=1}
port {port_num} tw inport show
port {port_num} initstate coldstart set {off=0|on=1|
remember=2}
port {port_num} initstate coldstart show
port {port_num} initstate repow er set {init_sta-
tus=0|current_state=1}
port {port_num} initstate repow er show
port {port_num} initstate delay set <num>
port {port_num} initstate delay show
port {port_num} repow erdelay set <num>
port {port_num} repow erdelay show
port {port_num} resettime set <num>
port {port_num} resettime show
port {port_num} w atchdog enabled set {off=0|
on=1}
port {port_num} w atchdog enabled show
port {port_num} w atchdog action set {off=0|re-
set=1}
port {port_num} w atchdog action show
port {port_num} w atchdog type set {w d_icmp=0|
w d_tcp=1}
port {port_num} w atchdog type show
port {port_num} w atchdog host set "{dns_name}" sets port w atchdog host target
port {port_num} w atchdog host show
port {port_num} w atchdog port set {ip_port}
port {port_num} w atchdog port show
port {port_num} w atchdog pinginterval set <num> sets port w atchdog ping interval
port {port_num} w atchdog pinginterval show
port {port_num} w atchdog pingretries set <num> sets port w atchdog ping retries
port {port_num} w atchdog pingretries show
port {port_num} w atchdog retrybooting set
{off=0|on=1}
port {port_num} w atchdog retrybooting show
port {port_num} w atchdog bootretries set <num> sets port w atchdog retry boot timeout
Smart PDU SP4120200 / SP7120200
enters cmd group "linesensor"
show s energy sensor of given line
sets line meter to label
show s label of line meter
enables messages on/off
show s if messages are enabled
sets maximum value for line meter
show s maximum value for line meter
sets minimum value for line meter
show s minimum value for line meter
sets hysterese value for line meter
show s hysterese value for line meter
enables beeper for line meter alarms
show s if beeper for line meter alarms is enabled
enters cmd group "port"
sets port to new state
show s port state
start reset sequence for port
toggles port
starts batch mode for port
cancels batch mode
sets port label name
show s port label name
sets port tw inport state to on/off
show s port tw inport state
sets port coldstart initialization
show s port coldstart initialization
sets port initialization for bank repow er
show s port initialization for bank repow er
sets port init delay
show s port init delay
sets port repow er delay
show s port repow er delay
sets port reset duration
show s port reset duration
sets port w atchdog to on/off
show s port w atchdog state
sets port w atchdog action
show s port w atchdog action
sets port w atchdog type
show s port w atchdog type
show s port w atchdog host target
sets port w atchdog TCP port
show s port w atchdog TCP port
show s port w atchdog ping interval
show s port w atchdog ping retries
sets port w atchdog retry booting to on/off
show s port w atchdog retry booting state
50
© 2016 U.T.E. Electronic GmbH & Co. KG

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Smart pdu sp7120200

Inhaltsverzeichnis