Herunterladen Inhalt Inhalt Diese Seite drucken

UTE Electronic Smart PDU SP4120200 Anleitung Seite 41

Inhaltsverzeichnis

Werbung

Spezifikationen
epc8226PortSw itchCount
epc8226PortStartupMode
epc8226PortStartupDelay
epc8226PortRepow erTime
epc8226Buzzer
epc8226ActivePow erChan
epc8226Pow erIndex
epc8226ChanStatus
epc8226AbsEnergyActive
epc8226Pow erActive
epc8226Current
epc8226Voltage
epc8226Frequency
epc8226Pow erFactor
epc8226Pangle
epc8226Pow erApparent
epc8226Pow erReactive
epc8226AbsEnergyReactive
epc8226AbsEnergyActiveResetta-
ble
epc8226AbsEnergyReactiveRe-
settable
epc8226ResetTime
epc8226Forw EnergyActive
epc8226Forw EnergyReactive
epc8226Forw EnergyActiveReset-
table
epc8226Forw EnergyReactiveRe-
settable
epc8226RevEnergyActive
epc8226RevEnergyReactive
41
Smart PDU SP4120200 / SP7120200
.58.1.3.1.2.1.4.x
The total number of sw itch actions ocurred on a Relay Port. Does not
count sw itch commands w hich w ill not sw itch the ralay state, so just
real relay sw itches are displayed here.
.58.1.3.1.2.1.5.x
set Mode of startup sequence (off, on , remember last state)
.58.1.3.1.2.1.6.x
Delay in sec for startup action
.58.1.3.1.2.1.7.x
Delay in sec for repow er port after sw itching off
.58.1.3.10.0
turn Buzzer on and off
.58.1.5.1.1.0
Number of suppported Pow er Channels.
.58.1.5.1.2.1.1.x
Index of Pow er Channel entries
.58.1.5.1.2.1.2.x
0 = data not active, 1 = data valid
.58.1.5.1.2.1.3.x
Absolute Active Energy counter.
.58.1.5.1.2.1.4.x
Active Pow er
.58.1.5.1.2.1.5.x
Actual Curent on Pow er Channel.
.58.1.5.1.2.1.6.x
Actual Voltage on Pow er Channel
.58.1.5.1.2.1.7.x
Frequency of Pow er Channel
.58.1.5.1.2.1.8.x
Pow er Factor of Channel betw een -1.0 and 1.00
.58.1.5.1.2.1.9.x
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
.58.1.5.1.2.1.10.x
L Line Mean Apparent Pow er
.58.1.5.1.2.1.11.x
L Line Mean Reactive Pow er
.58.1.5.1.2.1.12.x
Absolute Reactive Energy counter.
.58.1.5.1.2.1.13.x
Resettable Absolute Active Energy counter. Writing '0' resets all reset-
table counter.
.58.1.5.1.2.1.14.x
Resettable Absolute Reactive Energy counter.
.58.1.5.1.2.1.15.x
Time in seconds since last Energy Counter reset.
.58.1.5.1.2.1.16.x
Forw ard Active Energy counter.
.58.1.5.1.2.1.17.x
Forw ard Reactive Energy counter.
.58.1.5.1.2.1.18.x
Resettable Forw ard Active Energy counter.
.58.1.5.1.2.1.19.x
Resettable Forw ard Reactive Energy counter.
.58.1.5.1.2.1.20.x
Reverse Active Energy counter.
.58.1.5.1.2.1.21.x
Reverse Reactive Energy counter.
Integer32
RO
INTEGER
RW
Integer32
RW
Integer32
RW
Integer32
RW
Unsigned32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Gauge32
RW
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
© 2016 U.T.E. Electronic GmbH & Co. KG

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Smart pdu sp7120200

Inhaltsverzeichnis