Herunterladen Inhalt Inhalt Diese Seite drucken

UTE Electronic Smart PDU SP4120200 Anleitung Seite 42

Inhaltsverzeichnis

Werbung

Spezifikationen
epc8226RevEnergyActiveResetta-
ble
epc8226RevEnergyReactiveReset-
table
epc8226OVPIndex
epc8226OVPStatus
epc8226spActivePow erChan
epc8226spPow erIndex
epc8226spChanStatus
epc8226spAbsEnergyActive
epc8226spPow erActive
epc8226spCurrent
epc8226spVoltage
epc8226spFrequency
epc8226spPow erFactor
epc8226spPangle
epc8226spPow erApparent
epc8226spPow erReactive
epc8226spAbsEnergyReactive
epc8226spAbsEnergyActiveRe-
settable
epc8226spAbsEnergyReactiveRe-
settable
epc8226spResetTime
epc8226spForw EnergyActive
epc8226spForw EnergyReactive
epc8226spForw EnergyActiveRe-
settable
epc8226spForw EnergyReacti-
veResettable
epc8226spRevEnergyActive
epc8226spRevEnergyReactive
epc8226spRevEnergyActiveRe-
settable
Smart PDU SP4120200 / SP7120200
.58.1.5.1.2.1.22.x
Resettable Reverse Active Energy counter.
.58.1.5.1.2.1.23.x
Resettable Reverse Reactive Energy counter.
.58.1.5.2.1.1.x
None
.58.1.5.2.1.2.x
show s the status of the built-in Overvoltage Protection
.58.1.5.5.1.0
Number of Single Port Pow er Channels. Value is zero on EPC 8220 se-
ries.
.58.1.5.5.2.1.1.x
Index of Single Port Pow er Channel entries. Indices 0-5 mean Ports A1
to A6, 6-11 are Ports B1 to B6.
.58.1.5.5.2.1.2.x
0 = data not active, 1 = data valid
.58.1.5.5.2.1.3.x
Absolute Active Energy counter.
.58.1.5.5.2.1.4.x
Active Pow er
.58.1.5.5.2.1.5.x
Actual Curent on Pow er Channel.
.58.1.5.5.2.1.6.x
Actual Voltage on Pow er Channel
.58.1.5.5.2.1.7.x
Frequency of Pow er Channel
.58.1.5.5.2.1.8.x
Pow er Factor of Channel betw een -1.0 and 1.00
.58.1.5.5.2.1.9.x
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
.58.1.5.5.2.1.10.x
L Line Mean Apparent Pow er
.58.1.5.5.2.1.11.x
L Line Mean Reactive Pow er
.58.1.5.5.2.1.12.x
Absolute Reactive Energy counter.
.58.1.5.5.2.1.13.x
Resettable Absolute Active Energy counter.
.58.1.5.5.2.1.14.x
Resettable Absolute Reactive Energy counter.
.58.1.5.5.2.1.15.x
Time in seconds since last Energy Counter reset.
.58.1.5.5.2.1.16.x
Forw ard Active Energy counter.
.58.1.5.5.2.1.17.x
Forw ard Reactive Energy counter.
.58.1.5.5.2.1.18.x
Resettable Forw ard Active Energy counter.
.58.1.5.5.2.1.19.x
Resettable Forw ard Reactive Energy counter.
.58.1.5.5.2.1.20.x
Reverse Active Energy counter.
.58.1.5.5.2.1.21.x
Reverse Reactive Energy counter.
.58.1.5.5.2.1.22.x
Gauge32
RO
Gauge32
RO
Integer32
RO
INTEGER
RO
Unsigned32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO