Spezifikationen
epc8221TrapAddr
epc8221portNumber
epc8221PortIndex
epc8221PortName
epc8221PortState
epc8221PortSw itchCount
epc8221PortStartupMode
epc8221PortStartupDelay
epc8221PortRepow erTime
epc8221Buzzer
epc8221ActivePow erChan
epc8221Pow erIndex
epc8221ChanStatus
epc8221AbsEnergyActive
epc8221Pow erActive
epc8221Current
epc8221Voltage
epc8221Frequency
epc8221Pow erFactor
epc8221Pangle
epc8221Pow erApparent
epc8221Pow erReactive
epc8221AbsEnergyReactive
epc8221AbsEnergyActiveResetta-
ble
epc8221AbsEnergyReactiveRe-
settable
epc8221ResetTime
epc8221Forw EnergyActive
epc8221Forw EnergyReactive
39
Smart PDU SP4120200 / SP7120200
.56.1.1.1.2.1.2.x
DNS name or IP address specifying one Trap receiver slot. A port can
optionally be specified: 'name:port' An empty string disables this slot.
.56.1.3.1.1.0
The number of Relay Ports
.56.1.3.1.2.1.1.x
A unique value, greater than zero, for each Relay Port.
.56.1.3.1.2.1.2.x
A textual string containing name of a Relay Port.
.56.1.3.1.2.1.3.x
current state of a Relay Port
.56.1.3.1.2.1.4.x
The total number of sw itch actions ocurred on a Relay Port. Does not
count sw itch commands w hich w ill not sw itch the ralay state, so just
real relay sw itches are displayed here.
.56.1.3.1.2.1.5.x
set Mode of startup sequence (off, on , remember last state)
.56.1.3.1.2.1.6.x
Delay in sec for startup action
.56.1.3.1.2.1.7.x
Delay in sec for repow er port after sw itching off
.56.1.3.10.0
turn Buzzer on and off
.56.1.5.1.1.0
Number of suppported Pow er Channels.
.56.1.5.1.2.1.1.x
Index of Pow er Channel entries
.56.1.5.1.2.1.2.x
0 = data not active, 1 = data valid
.56.1.5.1.2.1.3.x
Absolute Active Energy counter.
.56.1.5.1.2.1.4.x
Active Pow er
.56.1.5.1.2.1.5.x
Actual Curent on Pow er Channel.
.56.1.5.1.2.1.6.x
Actual Voltage on Pow er Channel
.56.1.5.1.2.1.7.x
Frequency of Pow er Channel
.56.1.5.1.2.1.8.x
Pow er Factor of Channel betw een -1.0 and 1.00
.56.1.5.1.2.1.9.x
Phase Angle betw een Voltage and L Line Current betw een -180.0 and
180.0
.56.1.5.1.2.1.10.x
L Line Mean Apparent Pow er
.56.1.5.1.2.1.11.x
L Line Mean Reactive Pow er
.56.1.5.1.2.1.12.x
Absolute Reactive Energy counter.
.56.1.5.1.2.1.13.x
Resettable Absolute Active Energy counter. Writing '0' resets all reset-
table counter.
.56.1.5.1.2.1.14.x
Resettable Absolute Reactive Energy counter.
.56.1.5.1.2.1.15.x
Time in seconds since last Energy Counter reset.
.56.1.5.1.2.1.16.x
Forw ard Active Energy counter.
.56.1.5.1.2.1.17.x
OCTETS
RW
Integer32
RO
Integer32
RO
OCTETS
RO
INTEGER
RW
Integer32
RO
INTEGER
RW
Integer32
RW
Integer32
RW
Integer32
RW
Unsigned32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Integer32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Integer32
RO
Gauge32
RO
Gauge32
RW
Gauge32
RO
Gauge32
RO
Gauge32
RO
Gauge32
RO
© 2016 U.T.E. Electronic GmbH & Co. KG