4. TECHNICAL DATA

Supply voltage range
Supply current (no alarm condition)
@Vin=24VDC without back lighting
@Vin=12VDC without back lighting
Input voltage range auxiliary battery
Input current range (with supplied shunt)
Battery capacity range
Operating temperature range
Readout resolution:
Voltage (0 ... 135V)
Current (0 ... 10A)
Current (10 ... 500A)
Amp hours (0 ... 200Ah)
Amp hours (200 ... 2000Ah)
State-of-charge (0 ... 100%)
Time-to-go (0 ... 100hrs)
Time-to-go (100 ... 240hrs)
Voltage measurement accuracy
Current measurement accuracy
Potential free alarm contact
Mode
Rating
Dimensions:
Front panel
Body diameter
Overall depth
Net weight:
BMV
Shunt
Material
Body
Sticker
20
9.5 ... 95VDC
3 mA
4 mA
9.5 ... 95VDC
-500 ... +500A
20 ... 9999Ah
0 ... 50° C
voltage dependent
±0.1A
±1A
±0.1Ah
±1Ah
±0.1%
±1minute
±1hr
±0.3%
±0.5%
Normally open
60V/1A max.
69 x 69mm
52mm
31mm
70g
315g
ABS
Polyester