Press the end protectors (2017) and (1018)
onto the profile ends (4.9).
5R and 5L DOOR
Push the door glider (1014) onto both ends of
door bar (1060) (5.1).
Assemble the door as shown in diagram 5.
Connect door rollers (1015) to the door bar
(1062) using bolt (1004), washer (1009) and
nut (1007) (5.4).
Bolt door bar (1062) to upper bar (1059) (5.3)
and slide the door seal (2021) into the outside
side bar (2058) (5.6). Please check that for the
inside side bar, the part (2098) is used on the
right in (5R) and (2099) on the left in (5L).
Connect the door fixer (1111) as shown.
Loosen the door supports (2043).
The door rollers can now be slid into door
runner bar (1047) (5.7). Please ensure that the
door gliders are also running on the bottom
track (5.5).
Once the door is correctly in place, connect
nuts and bolts into the end of both door runner
bars (1047) as door stopper.
Adjust the door so that it moves freely.
6. ROOF VENTS
Connect the side bars (1065) and the top bar
(1064) depending on the glass thickness.
Till 4 mm, see (6.1). For and over 4 mm, see
(6.2).
Place the bolts to connect the bottom bar
(1066) in the prepared holes, and then slide
the glass into the tracks in side bars (1065)
(6.3).
Now connect bottom bar (1066), and control
that the window is totally square before
tightening all bolts.
Position the window in the ridge bar from one
end (6.4) and (6.5) and slide it to the required
position (6.6).
Connect the window sill (1063) with the extra
bolts in the roof bars (6.7).
Bolt the window opener (1067) to the bottom
bar (1066) using screws (1006) (6.8).
Place the plastic cap (1019) over the end of
the window opener (6.6) and connect both
window fixers (1016) onto the window sill
(1063) using screws (1006) (6.8).
7. GLAZING – CLEAR/FROSTED GLASS
Please note the already mentioned safety
precautions.
Press the glazing seals (1020) onto the alumi-
nium profiles (7.3) and cut to length.
001.01.0802
On the roof begin by positioning the glass at
the roof ridge and fix in place using the glazing
spring clips (1011) (7.2). The following sheet
must then be slid under the sheet directly
above it with the glass retaining clips (1012)
between the panes (7.1). Continue as shown
in the glazing plan.
If difficulties arise in placing the last glass
sheet, please check that those above have not
slipped down.
On the sides please begin from the bottom.
FINISHING
If desired, it is possible to seal the greenhouse
at the edges using silicon. Silicon is not in-
cluded.
Place the warning label inside the house.
A full range of greenhouse accessories, to help
you make the most of this product, is available
from your stockist. Please inform yourself as to
the possibilities.

SAFETY NOTICE

In the event of high wind conditions, close the
door and all vents.
COMMENTS
For the complete protection of your new
greenhouse, we advise you to include it in
your house insurance. Please take note of
possible building rules relating to the position-
ing of greenhouses.
Please stick the greenhouse model label pro-
vided onto the door bar (1062) after success-
fully assembling this product. This information
is important in the event that replacement
parts are later required.
Please keep these Assembly Instructions in
a safe place, for future reference!
Our policy is one of continuous improvement
and we reserve the right to change the specifi-
cations without prior notice.