4.2.1 Main switch (No. 7)
Position Ignition OFF: Unit is switched off, control via the opera-
tion insulation monitoring is not possible.
Position Ignition ON: the device is ready for operations with the
"ignition on". The device can now be operated by insulation monitoring.
Position Start (keyed): Continuing to turn the main switch to position
Start causes the power generating set to start. The main switch must
be pressed on the start position until the power generating set starts.
The main switch returns to the ignition ON position when released.
Attention: If the start process was not successful, you have two more
attempts before the starter lock prevents a further starting attempt for 30 sec-
onds in order to protect the starter. The remaining time will be displayed in this
process.
Switch the main switch back to position Ignition OFF after each use or after
exercise of the power generating set. In any case, the main switch must be set
back to position Ignition OFF, if the power generating set is taken out of service
or transported or stored in the vehicle.
4.2.2 Fuel level indicator
The fuel level indicator displays the fill level in the tank in the increments of 0-/25-/50-/
75- and 100%.