08.08.01
1. Test mode:
Manufacturer's default setting:
To test the functions of all additionally connected accessories
in the test mode, the preset delays are accelerated by factor 5
and the wind meter monitoring responds after 90 seconds.
2. Wind meter:
Manufacturer's default setting:
If the wind meter is activated, the wind LED permanently lights
up green. The wind safety function is disabled and menu
options 3 – 6 will not be not indicated.
3. Extended wind range:
Manufacturer's default setting:
This menu option is only available, if the wind meter is activated.
OFF: The wind speed threshold value can bet set between
10 and 40 km/h.
ON: The wind speed threshold value can bet set between
10 and 100 km/h.
4. Unit of the wind speed:
Manufacturer's default setting:
This menu option is only available, if the wind meter is activated.
14:31
Seite 81
Basic settings
ON / OFF
OFF
ON / OFF
ON
ON / OFF
OFF
km/h / m/s
km/h
- 81 -
Basic settings
5. Wind meter type:
Manufacturer's default setting:
This menu option is only available, if the wind meter is activated.
6. Wind response delay:
Manufacturer's default setting:
This menu option is only available, if the wind meter is activated.
Please note, that the wind speed threshold value must be
exceeded for the complete duration of the response delay
before the sunshade can retract.
7. Sun sensors:
Manufacturer's default setting UNI 12: 1
Manufacturer's default setting UNI 22: 2
Set the number of connected sun sensors.
8. Allocation of the sensors:
Manufacturer's default setting:
(only UNI 22 / UNI 22 Funk with 2 sun sensors)
A:
For both motor circuits, only the highest of the two sun
intensity values measured by sun sensor 1 applies.
B:
The values measured by sun sensor 1 apply for motor
circuit 1;
The values measured by sun sensor 2 apply for motor
circuit 2.
*
requires a special wind meter
G
G
Standard / Special*
Standard
0 – 10 seconds
0 seconds
0 / 1 / 2
A / B
B