The machine requires minimum maintenance
apart from the
following checks by the operator prior to use:
• DO NOT use aggressive
detergents,
acid, lye etc. during
cleaning
and
washing
and
take
particular
care
with
electrical parts.
• Supply
cord
- Regularly
inspect sheath,
plug and cord
anchorage
for damage or loose connection.
Only replace
the
supply
cord
with
the
type
specified
in
these
instructions.
• Brushes
- For maximum
life, wash the brushes regularly.
Ensure machine
is in Transport
mode when not in use.
Store additional
brushes
in a vertical
position
to avoid
bending
of bristles.
Check
for permanent
bending
of
bristles
in a particular
direction.
This may occur
if the
machine is operated for several days without removing the
brushes, which is not recommended.
If this occurs, reverse
the
brush
so that
the
bent
bristles
are automatically
straightened.
• Wiper
Blade
- After years of use the wiper blade may
wear. If this occurs the water collection
performance
will
decrease.
It should be replaced by an authorised
service
agent.
• Solution
tank
filter
(Standard)
- The
filter
prevents
clogging of the drip holes in the tank. Periodically clean the
filter to ensure uniform discharge of liquid. In case of non-
uniform discharge from the drip holes, back flush the tank
in running water. Clean the drip holes using wire or a blunt
pin.
• Solution
feed filter (Pump)
- The filter prevents clogging
of the spray nozzle and should
be periodically
cleaned.
Use pressurised air/water for cleaning.
• Nozzle maintenance
(Pump)
- If the spray of the nozzle
becomes
blocked, slide the nozzle cover off and remove
nozzle wash in clean water and clean using a pin and refit.
After sales service
Truvox machines
are high quality machines that have been
tested
for safety
by authorised
technicians.
It is always
apparent
that after longer working
periods,
electrical
and
mechanical
components
will show signs of wear and tear or
ageing.
To maintain
operational
safety
and reliability
the
following
service
interval has been defined:
Every year or
after 250 hours.
Under extreme
or specialised
conditions
and/or
insufficient
maintenance,
shorter
maintenance
Recommended
Spares &
Accessories
intervals are necessary. Use only original Truvox spare
parts. Use of other spare parts will invalidate all warranty and
liability claims. Should you require after sales service please
contact the supplier from whom you purchased the machine,
who will arrange service. Repairs and servicing of Truvox
products should only be performed by trained staff. Improper
repairs can cause considerable danger to the user.
Guarantee
Your product is guaranteed for one year from the date of
original purchase, or hire purchase, against defects in
materials or workmanship during manufacture. Within the
guarantee period we undertake at our discretion, to repair or
replace free of charge to the purchaser, any part found to be
defective, subject to the following conditions:
CONDITIONS
1. Claims made under the terms of the guarantee must be
supported by the original invoice/bill of sale issued at the
time of sale, or the machine Serial No.
2. For claims under this guarantee contact the supplier from
whom you purchased the product who will arrange the
appropriate action. Do not initially return the product as
this could result in transit damage.
3. Neither Truvox nor its distributor shall be liable for any
incidental or consequential loss.
4. This guarantee is governed by the laws of England.
5. This guarantee does not cover any of the following:
Periodic maintenance, and repair or replacement
of parts due to normal wear and tear.
Damage caused by accident, misuse or neglect, or
the fitting of other than genuine Truvox parts.
Defects in other than genuine Truvox parts, or
repairs, modifications or adjustments performed by
other than a Truvox service engineer or authorised
service agent.
Costs and risks of transport relating directly or
indirectly to the guarantee of this product.
Consumable items such as, brushes, drive discs,
filters and vacuum skirts.
This guarantee does not affect your statutory rights, or
your rights against the supplier arising from their sales or
purchase contract. Truvox International Limited policy is
one of continual product development and we reserve the
right
to
alter
specifications
without
prior
notice.
Item
MW240
MW340
MW340/Pump
MW440/Pump
Usage
All natural stone floors,
Standard brush -
ceramic, mosaic, wood,
black (2 required)
90-0127-0000
90-0130-0000
90-0130-0000
90-0387-0000
profiled rubber, vinyl, PVC
(First time cleaning);
smooth concrete
All natural stone floors,
ceramic, mosaic, wood,
Soft brush - grey
90-0133-0000
90-0131-0000
90-0131-0000
90-0388-0000
profiled
rubber, vinyl,
PVC
(2 required)
(Maintenance cleaning);
short pile carpet, marble
oranite
Side brush-
90-0134-0000
90-0132-0000
90-0132-0000
black (1 required)
90-0385-0000
For up-to-the-edge cleaning
Hard brush-
90-0089-0000
90-0089-0000
To suit individual floor
blue (2 required)
-
-
conditions, smooth concrete
Escalator brush -
90-0090-0000
90-0090-0000
90-0469-0000
For use on escalators
blue (2 required)
-
4 litre tank
90-0307-0000
-
-
90-0103-0000
Trolley
05-3395-0500
For easier transport
(for all models)
4

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Multiwash mw340 pumpMultiwash mw340Multiwash m440 pump

Inhaltsverzeichnis