settings foR tHe ContRol unit

The use of these settings is for version 3.12 of the firmware.
The settings could change in the future. If your firmware is a differnet version than 3.12,
please contact CARPetligHt GmbH.

switching on/off and standby-mode

Once the lamp is successfully connected to the control unit and that is connected to a
functioning power supply, the lamp is ready for use. Once the main switch on the control
unit has been activated, the CARPetligHt-Logo will appear in the display. The lamp always
starts in the On-mode and the illumination will be the same as the last set up which was
input into the control unit. This includes it´s brightness and color temperature.

Brightness and Color temperature

Once the control unit and lamp body have been successfully connected, the use of
brightness and color temperature settings can be seen in the display.
For setting the brightness please use the brightness control.
For setting the color temperature please use the color temperature control.
The color temperature can be seen in the display and is measured in Kelvin (K), and can
be controlled in 50 K increments. The wanted value is displayed in 100 K increments. The
small square which shows when the control knob is continuously adjusted shows the 50
K increments.

temperature display and overheating

The lamp is equipped with four thermo-sensors to prevent overheating.
The display shows the highest measured temperature at the sensors, and once the
lamp`s temperature exceeds 176°F (80°C), a warning sign will appear.
A slow blinking light in the display will indicate that the lamp is overheating.
Should the lamp´s temperature continue rising by another 41°F (5°C) after the beginning
of the warning period, the lamp will go into safety mode. The lamp will reduce its
brightness to 20% autonomously. Once the temperature has fallen to 172.4°F (78°C), the
lamp will automatically return to its previous brightness level.
Attention: this might lead to alternating dimming actions (up/down) if the lamps
thermal situation is not altered. for example, if the lamps airing/ventilation or cooling
doesn't change.
If the warning recures, use an alternative brightness level or lamp position to secure
a faultless operation. Turning down the dimmer a few percent should reduce the heat
noticeably.

selection using the menu function / standby-mode

Pressing down the stand-by button briefly, will put the lamp into stand-by mode and
switch the lamp off. Pressing down on the button again will turn the light back on to its
previous setup before the lamp was turned off. To switch the lamp off turn the main
switch off.