Installation
Connection in Ducting Version
When installing the ducting version, connect the
hood to the chimney using either a fl exible or rigid
pipe ø 150 or 120 mm, the choice of which is left to
the installer.
To install a ø 120 mm air exhaust connection,
insert the reducer fl ange 9 on the hood body
outlet.
ø 150
Fix the pipe in position using suffi cient pipe
clamps (not supplied).
Remove charcoal fi lters, if present.
Connection in Recirculation Version
without chimney:
For the recirculation version without chim-
ney, only the charcoal is additionally required.
Please call customer service to order the char-
coal fi lter.
Screw the fi lter cover 16 onto the air outlet, us-
ing four screws 12c supplied.
Fix the directional grille 8 on the fi lter cover air
outlet using the 2 screws 12d provided.
8
16
Ensure that the activated charcoal fi lters have
been inserted. (see parag. "Activated carbon
fi lter" in Filters and Maintenance chapter)
ø 120
9
12d
12c
with chimney:
All the items named in this procedure are
included in the recirculation kit. The correspond-
ing accessory numbers can be found at the end
of these operating instructions.
Put connection 15 into the connection support
7.3.
Insert the connection extension pieces laterally
14.1 in connection 15.
Make sure that the outlet of the extension
pieces 14.1 is horizontally and vertically aligned
with the chimney outlets.
Connect the air outlet connection 15 to the
hood body outlet using either a pipe ø 150 mm.
7.3
15
25
ø 150
Use the jubilee clips 25 to ensure a fi x connec-
tion between pipe and hood outlet and between
pipe and connection (15).
Ensure that the activated charcoal fi lters have
been inserted.(see parag. "Activated carbon
fi lter" in Filters and Maintenance chapter)
en
14.1
25