6. Packaging / 7. Starting, operation

6. Packaging

Has everything been supplied?
Check the scope of supply:
Completely assembled pressure switches; with flush version PS-20 including pre-assembled
sealings and protection cap.
Inspect the pressure switch for possible damage during transportation. Should there be any
obvious damage, inform the transport company and WIKA without delay.
Keep the packaging, as it offers optimal protection during transportation (e.g. changing installation
location, shipment for repair).
Ensure that the pressure connection thread and the connection contacts will not be damaged.
In order to protect the diaphragm, the pressure connection of the instrument PS-21 is provided with a special
protection cap.
Remove this protection cap only just before installing the pressure switch in order to prevent any
damage to the diaphragm or the thread.
Keep the protection cap of the pressure connection thread and the diaphragm for later storage or
transport.
Mount the protection cap when removing and transporting the instrument.

7. Starting, operation

Required tools: wrench (flats 27 or 41), screw driver
Diaphragm test for your safety
It is necessary that before starting the pressure transmitter you test the diaphragm visually, as this is a safety-
relevant component.
!
Pay attention to any liquid leaking out, for this points to a diaphragm damage.
Check the diaphragm visually for any damage (PS-21).
Use the pressure switch only if the diaphragm is undamaged.
Warning
Use the pressure switch only if it is in a faultless condition as far as the safety-relevant
features are concerned.