Herunterladen Inhalt Inhalt Diese Seite drucken

Specifications - netio 4 Schnellinstallationsanleitung

Vorschau ausblenden Andere Handbücher für 4:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Specifications

Power
Switched outputs
Fuse
Internal consumption
Output relay rating
NETIO 4C interfaces
NETIO 4 interfaces
NETIO 4All interfaces
Environment
Resettable fuse
The device is equipped with a resettable fuse. In case of output overload or a failure
of a connected device, the power is disconnected and the fuse button pops out. After
removing the problem (disconnecting the faulty load) and waiting for about 60
seconds, device operation can be restored by pressing the button.
90-240 VAC; 50/60 Hz; 15 A (10 A for NETIO 4C)
NETIO 4/4All:
NETIO 4C:
Built-in 15 A protection fuse (10 A for NETIO 4C)
Max 4.1 W
Micro-disconnection = µ (ohmic load)
1E5 switching cycles
Max impulse voltage 1.5 kV,
2x Ethernet RJ-45 10/100 Mbit/s
1x Ethernet RJ-45 10/100 Mbit/s
1x Wi-Fi 802.11b/g/n 2.4 GHz (ext. 2dBi antenna)
1x Ethernet RJ-45 10/100 Mbit/s
1x Wi-Fi 802.11b/g/n 2.4 GHz (3dBi, RSMA)
1x Bluetooth 4.0 LE 2.4 GHz (3dBi, RSMA)
IP30, Heat and fire resistance class 1
Operating temperature 0 — 50 °C
Suitable for pollution level 2
For continuous use at altitudes up to 2000 m
Does not require additional cooling
10
15 [8] A total
8 [8] A per each power socket
10 A total / 8 A per outlet

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

4all4c

Inhaltsverzeichnis