Herunterladen Inhalt Inhalt Diese Seite drucken

Mounting The Measuring Device; Required Tools - Endress+Hauser Liquiphant FTL31 Anleitung

Vorschau ausblenden Andere Handbücher für Liquiphant FTL31:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Installation
5.2

Mounting the measuring device

Service in accordance with WHG: Prior to mounting the device, pay attention to the WHG
approval documents. The documents can be found in the Download Area of the Endress
+Hauser website:
5.2.1

Required tools

• Open-ended wrench: only turn by the hex bolt when screwing in.
Maximum torque: ≤ 30 Nm (22 lbf ft).
• Socket wrench: The socket wrench AF32 is available as an accessory →  64.
Pay attention to the temperature and pressure specifications for seals used at the
customer site.
View, dimensions in mm (in)
32 mm
1
Flat seal
2
Weld-in adapter
32 mm
52
www.endress.com → Download
L1
L2
2
1
66.4 (2.6)
47.9 (1.8)
Description
Thread accessory weld-in adapter
Example G ¾" (example in graphic on left)
• L1: 63.9 mm (2.52 in)
• L2: 38.0 mm (1.5 in)
G 1"
• L1: 66.4 mm (2.61 in)
• L2: 48.0 mm (1.89 in)
Pressure and temperature (maximum):
+25 bar (+362 psi) at +150 °C (+302 °F)
+40 bar (+580 psi) at +100 °C (+212 °F)
When using a weld-in adapter with flush-mounted
seal, the flat seal (1) supplied must be removed
A0023245
from the thread.
Metric thread in customer nozzle
Example G 1"
Pressure and temperature (maximum):
+40 bar (+580 psi) at 150 °C (302 °F)
A0022026