Installation
5.1.4
Buildup
Make sure that the installation socket does not exceed a certain length so that the tuning fork
can project freely into the vessel.
Possibilities for optimization:
• A vertical orientation of the point level switch keeps buildup to a minimum.
• Preferably flush-mounted on vessels or in pipes.
 17
Buildup on tank wall, pipe wall and tuning fork
5.1.5

Weld-in adapter with leakage hole

If installed horizontally, ensure that the leakage hole is pointing down. This allows leaks to be
detected as quickly as possible.