3. SHUTDOWN AT THE END OF THE WORK
SHORT DURATION SHUTDOWN
1 -
Decrease the material pressure of air regulator (D) until reading 0 bar / 0 psi on the gauge (E).
2 -
Trigger the spray gun to depressurize the system.
3 -
Unscrew the spray gun air regulator (F) or disconnect the spray gun air inlet.
4 -
Remove the aircap from the spray gun, (aicap and nozzle for Airmix ® spray gun) and soak it
into solvent.
LONG DURATION SHUTDOWN
1 -
Decrease the air regulator (D) until reading 1 bar / 14.503 psi on gauge (E).
2 -
Unscrew the spray gun air regulator (F) or disconnect the spray gun air inlet.
3 -
Remove the spray gun aircap, (aircap and nozzle for AIRMIX ® spray gun) and soak it into
solvent.
4 -
Open the drain valve. The pump must operate slowly. If the speed is too high, decrease the air
regulator (D) pressure.
5 -
Remove the suction rod and the drain rod from the material container and immerse them in a
solvent-filled container. Take all the appropriate precautions in the presence of flammable
solvents.
6 -
When the solvent flows out regularly, close the drain valve.
7 -
Point the spray gun towards the material container and press the gun trigger. When the solvent
flows out, point the spray gun towards the recovery container.
8 -
When the solvent flows out, release the spray gun trigger.
Nota : If the pump is a intensive™ one, release the spray gun trigger when the pump is
9 -
Fully unscrew the air regulator (D) and shut off the main compressed air valve (valve H).
10 - Press the spray gun trigger to decompress the hoses. Therefore, the pump and the hose remain
filled with solvent at the atmospheric pressure
4. SAFETY DEVICE
Guards (air motor cover, coupling shields, housings ...) have been designed for safe use
The manufacturer will not be held responsible for bodily injury or failure and / or damage
to property due to removal or partial removal of the guards
A relief-valve (setting : 6,5 bar / 94 psi) is fitted on the pump air motor - thus protecting this one from an
overpressure which could damage it.
KREMLIN REXSON
in a low position. To prevent from damaging the seals when starting the pump,
the piston must be immersed into solvent.
of the equipment.
- 4 -
N° : 578.008.120-UK-1106