AIR MOTOR

Guards (air motor cover, coupling shields, housings ...) have been designed for
The manufacturer will not be held responsible for bodily injury or failure and / or
damage to property due to removal or partial removal of the guards
REVERSING BLOCK (MOTOR) (REFER TO DOC. 573.045.050 OR 573.046.050)
Disassemble cover (32) by removing 3 screws CHc (33).
Dissociate female yoke (12) from reversing block lever (9).
Dismount reversing block by removing screws (10 and 8).
Reinstall the new reversing block in the reverse order of the disassembly sequence.
CAUTION : The number of spirals must equally be distributed on each fastening parts in
order to get the above dimension.
Before reassembing the different components :
Clean the parts with the appropriate cleaning solvent.
-
-
Install new seals if it is necessary, after having lubricated them with PTFE grease.
Lubricate the piston and the inside of the cylinder to prevent from damaging the seals.
-
-
Install new parts if it is necessary.
KREMLIN REXSON
safe use of the equipment.
31.85 mm ±0.5
- 3 -
N° : 578.167.110-UK-1411