5.2.2 Bending procedure for JRG Sanipex MT pipes d16-d40

Marking of the radian measurement
corresponding to the dimension.
(Refer to technical document,
page 64).
Insert the pipe into the bending
template (pay attention to the centre
of the bend).
Attention: Before bending, align the
rotating pin prism in the direction
of the bending template.
Danger:
Piston running out!
Human limbs could be injured! The bending tool must only be operated with the
control cable connected and using the start button (30)!
Remark:
Slewing range pipe shank
When bending, take into consideration the swivelling range of the free pipe legs!
80
Fix the bending angle and adjust the
slide to the appropriate dimension
and fix with the adjusting screw.
Push the start button (30) on the
bending tool and hold it pushed.
The bending tool automatically
terminates the bending process when
the bending angle adjusted has been
reached. When the start button (30)
is released, the bending process is
immediately aborted. The process
can be continued and terminated by
renewed pushing and holding of the
start button.