Herunterladen Inhalt Inhalt Diese Seite drucken

Jrg Sanipex Mt Installation Procedures; Jrg Sanipex Mt Joining Technology; Installation Procedure Jrg Sanipex Mt D16-D40 - GF JRG Sanipex MT 4810.000 Bedienungs- Und Wartungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

5

JRG Sanipex MT installation procedures

5.1 JRG Sanipex MT connection technology

5.1.1 Installation procedure JRG Sanipex MT d16-d40

Cut JRG Sanipex MT pipe with
customary or with JRG pipe cutter to
the desired length.
Insert the JRG Sanipex MT pipe end
into the expansion tool right up to the
stop, close the clamping lever.
Start the expansion process by briefly
pushing the start button (4) on the
hydraulic device.
Remark:
Expanding process break off
A repeated pushing of the start button aborts the expansion process.
Following an abortion, the hydraulic device has to be switched off and then on again
with the mains switch (21).
Warning:
Incorrectly formed pipe flares
Incorrectly formed pipe flares must not be flared again!
74
Slide the union nut onto the
JRG Sanipex MT pipe.
Open the clamping lever and remove
the flared JRG Sanipex MT pipe
from the expansion tool.

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading