Function
Program Comfort
.
Water flow starts by pressing the push-button,
the water flow remains as long as the user
stays in the active range.
OFF
activation by push-button (ON = activation by close range reflex)
OFF
hygiene flushing deactivated
OFF
continuous flow deactivated
OFF
self-close function deactivated
ON
choice of activation - dip 6
ON
shower function
Program Self-close
.
Water flow starts, when the user
presses the push-button.
OFF
activation by push-button
OFF
hygiene flushing deactivated
OFF
continuous flow deactivated
ON
self-close function activated
ON
choice of activation - dip 6
ON
shower function
16
(Standard)
.
.
.
.
.
.
.
As soon as the user leaves the active range, the
water flow will be deactivated and stops after
the adjusted maximum flushing time
respectively. The water flow can also
stopped by the push-button.
.
.
Water flow stops, as soon as the user
operates the push-button or after the
adjusted maximum flushing time.