Symptom
There is noise in the
audio output from
the digital device that
is connected to the
adapter.
There is no audio
output to the
PHONES connector.
When the monitor
output selector is set
to 1, audio from the
tuner 2 is mixed with
the audio from the
tuner 1.
Meanings
The DWR-S01D inserted
in the adapter and the
digital device that is
connected to the adapter
are not in synchronization.
The WORD SYNC
connector is not 75-ohm
terminated.
The monitor level control
is turned down.
The tuner that is currently
turned off is selected by
the monitor output
selector.
The monitor output
selector is set to 2 when
the WRR-855 is attached
to the adapter.
"RX1+2" is selected on the
ANALOG OUTPUT1
function of the DWR-
S01D.
Remedy
If the connected device is not
compatible with the asynchronous
input (i.e., the sampling rate
converter is not equipped), use the
word clock signal to synchronize
the device.
When the DWR-S01D that is
inserted in the adapter is the end
device or when the master word
clock signal is input to this adapter
only, add the 75-ohm termination to
the WORD SYNC connector by
using the UTILITY menu of the
DWR-S01D.
Adjust the monitor level by using
the monitor level control of the
adapter.
Check the POWER switch for the
corresponding tuner of the DWR-
S01D.
The WRR-855 is a single-channel
receiver. Thus, no audio is output
when the monitor output selector is
set to 2.
On the DWR-S01D, select "RX1"
on the ANALOG OUTPU1 function
of the UTILITY menu.
When "RX1+2" is selected, audio
from the tuner 1 and 2 are mixed
regardless of the monitor output
selection.