Water connection

The appliance is only approved for heating water
with a speciic electric resistance of ≥ 1 300 Ωcm
at 15 °C. Your water utility company can give you
information about the speciic water resistance.

Installation

Ensure the axial it of the connection pipes in the
nozzles.
Tighten the union nuts on the nozzles with an
open-end wrench and counter hold with a suit-
able open-end wrench.
The T-piece (for the pressurized connection)
and lexible connection hose are available
commercially.
pressurized (closed)
22
en

Controlling temperature

The supply temperature (probably lower in winter)
and pressure luctuations can inluence the tem-
perature of the water leaving the tap.
F2
F1
Use an unpressurized tap for the unpressurized
connection, e. g. the tap available as a special
accessory (Single-lever mixer tap BZ13061,
Two handle ixture BZ13051).
Exchange the perlator from the tap ixture with
the supplied aerator to change the spray pattern
of the tap.
Turn the valve slowly in the closed direction for
higher temperatures (F1).
Add cold water for lower temperatures (
unpressurized (open)
F2).
F2
F1