Problem
The temperature in the
freezer is too low.
The temperature in the
freezer is too high.
There is too much frost.

Closing the door

1. Clean the door gaskets.
2. If necessary, adjust the door. Refer to "In-
stallation".

Technical data

Dimension of the recess
Rising Time
The technical information are situated in the
rating plate on the internal left side of the ap-
pliance and in the energy label.

Installation

Read the "Safety Information" carefully
for your safety and correct operation of
the appliance before installing the
appliance.
Possible cause
The Fast freezing function is
switched on.
The temperature regulator is not
set correctly.
The Fast freezing function is
switched on.
The temperature regulator is not
set correctly.
The door is not closed correctly.
The product temperature is too
high.
Many products are stored at the
same time.
Products are too near to each
other.
Food is not wrapped correctly.
The door is not closed correctly.
The temperature regulator is not
set correctly.
Height
Width
Depth
Refer to "Fast freezing function".
Set a higher temperature.
Refer to "Fast freezing function".
Set a lower temperature.
Refer to "Closing the door".
Let the product temperature de-
crease to room temperature before
storage.
Store less products at the same
time.
Store products so that there is cold
air circulation.
Wrap the food correctly.
Refer to "Closing the door".
Set a higher temperature.
3. If necessary, replace the defective door
gaskets. Contact the Service Force Cen-
ter.
1225 mm
560 mm
550 mm
24 h
Positioning
Install this appliance at a location where the
ambient temperature corresponds to the cli-
mate class indicated on the rating plate of the
appliance:
17