4.1 Electrical connection

The dishwasher's electrical connection, and that of eventual supplementary apparatus, is to be
entrusted to authorized and qualified personnel, with respect to the norms in vigor; the technical
regulations for the connections are also to be observed.
The total power installed is given upon the apparatus' technical data label.
Other apparatus must not be protected together with the dishwasher.
The user must provide for the installation, according to the norms in vigor, of a main electrical power
switch and of a differential switch compatible with the machine's characteristics.
These switches must be installed near the dishwasher, be easily accessible after installation and
guarantee complete disconnection from the electrical supply in category III over voltage conditions.
Caution!!!
The dishwasher is free of electrical current only when the main switch is off.
-
Connect the apparatus to the usage equalizer. The
back of the machine.
-
The protection conductor (PE) is yellow-green in color, the neutral conductor (N) is blue and the
phase conductors (L1, L2, L3) are black, gray and brown.
FIRST STARTUP
The electrical protection system must be subjected to a functional test before use. The installation must be
performed and/or verified by the authorized reseller who will be responsible for the first startup and for the
instructions relative to the dishwasher's operation.

PREPARATION FOR USE

Important:
The rinse-aid metering unit comes equipped in all models
while the detergent metering unit comes equipped in only
some models.
If both metering units are present, position the external
detergent and rinse-aid containers and insert their
respective suction tubes located at the back of the machine.
Red tube: detergent
Transparent tube: rinse-aid
Before inserting the tubes into the containers, apply the
weights (necessary to keep the tubes at the bottom of the
container) and the filters as indicated in the diagram.
For adjustments, use the adjustment screws indicated in the diagram. It is
recommended that adjustments be performed by personnel from the companies who
have supplied the detergent products.
If the detergent metering unit did not come pre-installed, it can be installed at a later
time by ordering the relative KIT.
Alternatively, an external metering unit can be connected by means of an electrical
connection with a 2x0.5 mm type H05 RN-F cable. This cable must be inserted through
the passage indicated in the TECHNICAL CHARACTERISTICS scheme and
connected in accordance with the electrical scheme furnished with the dishwasher.
The metering unit must be 230V/50Hz with a maximum absorbed power of 15W.
Connect the external detergent metering unit to the dishwasher through the red tube cited above.