PUTTING INTO OPERATION

Unpacking
• Carefully remove the unit from its box.
• Remove the unit from the plastic bag.
• Review the information given on the rating plate about the mains supply.
• Use the original packaging for storing the appliance if you do not use it all year round.
Putting into operation
Find the ideal location for your appliance:
• Do not place it directly next to a radiator or on a floor with floor heating. The moisture of the mist
can damage the floor surface (6 and 7) (see Safety Instructions).
• The mist outlet must not be pointed directly at plants or other objects. Keep a distance of
at least 50 cm) (10).
• Soak the demineralisation cartridge in a bowl of water for at least 24 hours before using it.
The granules have to absorb water to reach full performance.
• On average the demineralisation cartridge should be replaced every 2-3 months.
This interval can be shorter or longer depending on the hardness of your water.
• Read the instructions under «Filling the Tank» for filling the water tank (12).
• Place the water tank onto the base (13).
• Insert the plug into the mains socket and switch on the appliance using the on/off switch (15).
• The appliance will reach full capacity about 10 to 15 minutes after being switched on.
• Make sure that the power cord is not pinched anywhere (9). Do not operate the appliance if
the cord is damaged (2).
Description of the appliance
Mist outlet (rotating)
Water tank
Evaporation chamber
Demineralisation cartridge
Water tank cap
Ionic Silver Stick
®
(optional)
Control panel
Main body
40
Solis_Digisonic_Betriebsanleitung.indd 40-41
Filling the tank
Always switch off the appliance before removing the water tank.
Do not reach inside the nebuliser space while the appliance is running!
Do not operate the appliance when the water tank is empty! When the water reaches the minimum
level, the unit switches off automatically.
• Make sure that there are no foreign objects inside the water tank.
• Remove the water tank cap from the tank (11). Fill the tank with clean, cold tap water (12).
Close the cap of the water tank securely! Place the water tank onto the base (13).
Do not add any additives to the water (14)!
• Insert the plug into the power socket and switch on the appliance (15).
Figure 10
Figure 13
Figure 16
Water quality maintenance (recommended optional accessory)
The Ionic Silver Stick
water quality maintenance in all SOLIS humidifiers. The ISS begins working as soon as it comes into
contact with water – even if the unit is switched off. The ISS is intended exclusively for use in humidifiers.
Look at picture 16 for the position of the ISS in the appliance. Do not reach inside the nebuliser space
during operation. Switch off the unit first.
Brush
Membrane
Do not use additives
Nebuliser space
Water additives (e.g. essential oils, fragrances, water conditioners etc.) must NOT be used! Even a small
amount can cause damage to the tank material. The material is not suitable for the use of such additives.
One drop is enough to damage the tank and render the appliance unusable. Appliances that are damaged
by such additives will not be covered by the manufacturer's warranty.
Figure 11
Figure 14
®
(ISS) utilizes the antimicrobial property of silver and provides a year of optimum
Figure 12
Figure 15
41
27.05.10 09:58