Operation
Use
the
high
suction
concentrated kitchen vapours. It is recommended
that the cooker hood suction is switched on for 5
minutes prior to cooking and to leave in operation
during cooking and for another 15 minutes
approximately after terminating cooking.
1
ON/OFF motor
Pressing the button, the hood turns on at
speed 1.
Pressing the button during functioning, the
hood turns OFF.
2
Speed Increase
Pressing the button the hood passes from the
OFF state to speed 1.
Pressing the button (hood in ON state) the
motor speed is increased from speed 1 to
intensive.
To each speed corresponds the ignition of the
respective led.
Speed 1 led L1
Speed 2 led L2
Speed 3 led L3
Intensive Speed led L4 (flashing)
The intensive speed is timed. The standard
timing is 5', at the end of which the hood
positions itself to speed 2.
To deactivate the function before the time
expires press key 2, the hood positions itself to
speed 1, pressing key 1 the hood will turn off.
3
ON/OFF lights
4
Speed timing
speed
in
cases
5
Function state indicator
of
Speed Timing
The timing of the speed is enabled by pressing key
4, once the timing expires the hood turns off.
The timing is subdivided as follows:
Speed 1 - 20 minutes (led L1 flashing)
Speed 2 - 15 minutes (led L2 flashing)
Speed 3 - 10 minutes (led L3 flashing)
Intensive Speed - 5 minutes (led L4 flashing)
During the timed functioning pressing key 1 the
hood turns off, if you press key 2 or key 4 the hood
returns to the set speed.
Grease trap Signal
After 40 hours of operation the led L5 turns on.
When such signal appears the installed grease
trap needs to be washed.
To reset the signal hold down key 1 for 3".
Carbon filter Signal
After 160 hours of operation the led L5 flashes.
When such signal appears the installed carbon
filter must be substituted.
To reset the signal hold down key 1 for 3".
In the case of both filters signalling at the same
time, the led L5 will indicate the alarms alternately
remaining on for 3" and subsequently flashing 3
times.
The reset takes place by carrying out the
procedure described above 2 times.
The first time resets the grease trap signal, the
second resets the carbon filter signal.
In the standard mode the carbon filter signal is not
active.
In case one uses the hood in filter version is it
necessary to enable the carbon filter signal.
Carbon filter signal activation:
Position the hood in OFF and simultaneously hold
down keys 1 and 4 for 3".
The led L1 and L2 will flash for 5".
Carbon filter signal deactivation:
Position the hood in OFF and simultaneously hold
down keys 1 and 4 for 3".
The led L1 will flash for 2".
Temperature Alarm
The hood is equipped with a temperature sensor
that activates the motor to speed 3 in the case that
the temperature in the control zone becomes too
elevated.
The alarm condition is indicated with the sequential
flash of the leds L1, L2, L3.
This condition remains until the temperature falls
10