Dimensions and views
BVS Installation
Mount the sensor using BVS Z-MB-01 mounting bracket
and BMS CS-M-D12-IZ clamping cylinder
Please install the BVS at an angle of 5 to 15 degrees from the vertical
axis of the object.
Install the BVS sensor as close as possible to the object. It is recom-
mended to maintain the minimum distance of 50 mm however.
Do not install the sensor in a location in which the object is exposed
to direct sunlight or strong ambient light.
To attach the sensor, use 4 M4 x 6 mm screws, which are included
with the sensor.
At working distances of greater than 300 mm we recom-
mend use of an additional external light.
Overview of models
Ordering
Model code
Focal length
code
in mm
BVS0001
BVS ID- 3- 001-E
8
BVS000T
BVS ID- 3- 003-E
12
BVS000Y
BVS ID- 3- 007-E
16
BVS001M
BVS UR-3-001-E
8
BVS001N
BVS UR-3-003-E
12
BVS001L
BVS UR-3-005-E
6
BVS001P
BVS UR-3-007-E
16
Readable codes
Barcodes
Interleaved 2-of-5, Code 39, Code 128,
Pharmacode, Codabar, EAN8, EAN13,
EAN128, UPC- A & UPC-Et
Stacked Codes
PDF-417
2-D Codes
Datamatrix ECC 200, QR Code (Mode 1,
Mode 2) , Micro QR Code
Size of field of view and mininmum module sizes of bar code and
DMC & QR, Size of field of view : horizontal x vertical.
Type 005 (6 mm)
Working
Size of field
min. module sizes (mm)
distance (mm)
of view (mm))
bar code
50
34x 25
100
68x51
200
135x101
500
338x253
1000
676x507
Type 001 (8 mm)
Working
Size of field
min. module sizes (mm)
distance (mm)
of view (mm)
bar code
50
24×18
100
48×36
200
96×73
500
240×182
1000
480×360
Type 003 (12 mm)
Working
Size of field
min. module sizes (mm)
distance (mm)
of view (mm)
bar code
50
16×12
100
32×24
200
64x48
500
160×120
1000
320×240
Type 007 (16 mm)
Working
Size of field
min. module sizes (mm)
distance (mm)
of view (mm)
bar code
180
43x32
200
48x36
500
120×90
700
168×126
1000
240×180
PNP
n
Electrical
connections
n
IMPORTANT: Never connect or disconnect PWR IO while power is on!
n
"PWR IO" connector: M12 8-pin panel connector (male):
n
(power and in-/outputs)
n
Pin
Function
n
n
1
RS 232 Rx
2
24 V DC
3
Triggeroutput
(Ext. Illum.) or
Output 4
4
Output 1
5
Output 2
6
RS 232 Tx
7
Ground (0 V=)
8
Ext. Triggerinput
► Connect the PWR IO as shown below. Connect the cable shield
to ground!
► To set the sensor parameters you must connect the "TO PC"
DMC & QR
connector to the PC using an Ethernet cable (recommended:
0,09
0,18
BCC M415-E834-AG-672-ES64N8-050). The cable may be
0,18
0,37
removed once startup is complete.
0,37
0,74
0,92
1,85
1,85
3,70
DMC & QR
0,07
0,13
0,13
0,26
0,26
0,53
0,66
1,31
1,31
2,63
DMC & QR
0,04
0,09
0,09
0,18
0,18
0,35
0,44
0,88
0,88
1,75
DMC & QR
0,12
0,24
0,13
0,26
0,33
0,66
0,46
0,92
0,66
1,31
Connecting the RS232:
► Connect Sensor PIN 1 RS232 Rx with the RS232 Tx Pin of the
Rx.
Connect sensor ground to the ground on the opposite side (same
PLC or PC and connect Sensor Pin 6 RS232 Tx with the RS232
potential).
Wire colors
If RS232 is not been used:
BCC M418
Connect RS232 Rx with 0V.
White
Brown
Technical Data
Green
Electrical data
Operating voltage Us
Yellow
Ripple Upp
Grey
Pink
No-load current
Blue
Digital inputs
Red
Switching outputs
Output current
Output saturation voltage
Output signal for ext. light
Parameter setting interface
Datainterface
Configuration
Typical detection rate [Hz]
Optical data
Image sensor
Working distance
Field of View
BVS displays
Internal light
Ambient data
Enclosure rating per IEC 60529:
Reverse polarity protected
Short circuit protected
Ambient temperature Ta
e temperature
Contact
Germany
Balluff GmbH
Schurwaldstraße 9
24 V DC ± 10%
73765 Neuhausen a.d.F.
Telefon +49 7158 173-370
1 V max with light
Telefax +49 7158 5010
2 V max without light
service@balluff.de
< 200 mA at 24 V DC
1x Trigger
www.balluff.com
2 x PNP-transistor, Switching
function configurable;
1x Trigger output or switching
output 24 V configurable
100 mA max per output
< 2 V
Trigger signal PNP 24/0 V DC
1x M12 4-pin D-coded; Ethernet
10/100 Base T
Default IP: 172.27.101.208
Subnet : 255.255.0.0
RS-232: 9.6 -115.2 kBaud;
Ethernet TCP/IP: 10/100Mbit
Base-T
BVS ConVis Version 1.5 for
Windows XP or Windows 7
3 - 40 (depending on processing
function)
CMOS - BW - VGA 640x480
50 – 1000 mm; use of external
light recommended at 300 mm
and beyond
see overview of models
Led No. Color
Function
1
Green
Power On
2
Orange Output 1
3
Orange Output 2
4
Green
Configuration
LED, direct light, switchable
IP 54
YES
YES
-10 °C ... +55 °C
-25 °C ... +75 °C
USA
Balluff Inc.
8125 Holton Drive
Florence,
Kentucky 41042-0937
Phone 8 59/7 27-22 00,
1-8 00-5 43-83 90
Fax 8 59/7 27-48 23