3.
INSTALLATION
THE BURNER MUST BE INSTALLED IN CONFORMITY WITH LEGISLATION AND LOCAL STANDARDS.
3.1
WORKING POSITION
The burner is designed for operation in positions 1 and 2 only.
Installation 1 is the preferred option as it is the only one that enables maintenance to be performed as described
later on in this manual.
Operation is possible with installation option 2 though maintenance cannot be performed with the burner
connected to the boiler.
Note that any other installation position is likely to hinder the unit's proper operation.
Installations 3, 4 and 5 are prohibited as safety is compromised.
1
3.2
BOILER FIXING
To fit the burner to the boiler it is necessary to carry out the following:
®
Put on the flange (1) the screw and two nuts, (see fig. 3).
®
Widen, if necessary, the insulating gasket holes (4, fig. 4).
®
Fix the flange (1) to the boiler door (3) using screws (5) and (if necessary) the nuts (2) interposing the
insulating gasket (4), (see fig. 2).
®
After installation ensure that burner is lightly inclined as in figure 5.
Fig. 2
Fig. 3
3072
2
3
4
4
GB
5
D5012
Fig. 4
S7071
D5025
Fig. 5
D7088