Typical Home and Office EMF Levels
The maximum exposure limits shown above are much higher than
levels you would typically encounter. Some authorities recommend
much lower levels for long-term exposure, but as yet there is no
consensus on safe levels. Generally, when measuring homes or
offices,only the actual areas where people spend time (or where
EMF-sensitive equipment is to be located) are important. In the
middle of a typical home or office, magnetic field is usually less
than 5.0 mG, electric field is usually less than 20 V/m, and RF is
usually less than 5.000 mW/m2.
Function
Magnetisch
Elektrisch
RF/Microwave
Batterie
Temperature
Frequency Range
Strength Range
Accuracy
Resolution
Frequency Range
Strength Range
Accuracy
Resolution
Frequency Range
Maximum Range
Accuracy
Resolution
Dimension
Weight
Usage time
Temperature range
EMF Meter
40Hz —200Hz
00.1-99.9mG
±4%,50hz /60hz
0.1mG
40Hz —100KHz
1-999V/M
±5% ,50hz /60hz
1V/M
20MHz-6GHz
19.999mW/m²
±20%
0.001mW/m²
189 mm×53.8mm×35mm
approx. 180 g
( including battery )
>10h
0℃~70℃ / 32℉~158℉