EN
Timer
When a timer is set, the cooking zone switches off
after a set time between 1 min and 1 h 59 min.
Setting the timer
9 Hob switched on
9 Cooking zone set
Press
.
X
X
„_00" flashes in the middle of the display.
Touch
to increase the timer duration, touch
X
X
to reduce the time.
When you press
illuminated in the display.
Changing the timer
9 Timer set
Press the active cooking zone of the timer that
X
X
you want to change.
Press
.
X
X
Change the timer duration using
X
X
Bridging function
The bridging function allows two individual cooking
zones to be switched on to be adjusted together.
Press the bargraphs of the two cooking zone.
X
X
The display near the two zones shows „[" on
one side and „]" on the other side.
If one of the cooking zones is already running when
the bridging function is switched on, the power level
and operating time of this cooking zone will be used
for both zones. If both cooking zones are already
running, the operating times are cleared in the power
level displays.
Child proof lock
9 Appliance switched on
Touch
for few seconds until an acoustic signal
X
X
is emitted.
The display is locked. When the display
switches off in this state, the lock function will
still be active once you restart the hob.
To deactivate the childproof lock, press
X
X
few seconds.
for the first time „1" is
and
FH FS 864 / FH FS 865
Power management
The power management is based on the principle
that the last entry of the touch control is requested
by the induction with top priority. That means
that previous actions and settings made for the
other cooking zones are reversed automatically,
if necessary. Thus a parboiling boost or a boost
request may be reduced on a different cooking zone
than the one currently in operation to a performance
corresponding to a phase of ≤ 3.7 KW (total
performance).
If the induction system identifies the necessity of
reducing power of a cooking zone, the cooking stage
flashes on the corresponding display and provides
a correction period of 3 sec. After that power is
reduced automatically to a minimum cooking stage.
If the setting is adjusted within the correction period,
the power management checks the settings again.
.
In case of a new setting leads to further power
reduction necessity, the correction period starts
again. If no automatic correction needs being made
to the cooking zone setting, the flashing stops
immediately and the original value remains as a
steady display indication.
Should the situation change again on the power
reduced cooking zone, no automatic power increase
is effected.
Note: If the nominal power of two connected
cooking zones is higher than the power maximum of
a power unit (e.g. 210 mm/2.3 kW & 180 mm/1.8 kW), the
power management described above is not able to
function correctly in the case of a necessary power
reduction due to overheating!
for a