Herunterladen Inhalt Inhalt Diese Seite drucken

Ardic 042-D Betriebsanweisung Seite 9

Luftheizung
Inhaltsverzeichnis

Werbung

W.'
v
Fault type:
The heater ctarts and
lgnltec but ctopc
eoon
after
The ignition glow plug
stays
on,
where-
upon
the
safety
circuit
stops
the com-
bustion.
Check
if
the
flame
sensor
window
is
dirty.
lf
so,
clean.
At
lasting faults contact
a
qualified
ser-
vice workshop.
Routlne
een
lce
The
routine
service
should be canied
out
after
400
hours
of operation, or
at
least
once
a
year.
The
service includes:
Removal
of
the burner unit,
cleaning
and
checking
Checking
and
cleaning
the
heat
exchanger,
the glow plug and
the
flame
sensor.
Checking
the
heater installation
to
ensure:
-
that
all
components
are
securelY
attached.
-
that
the
air
hoses
are
not
blocked.
-
that the combustion air intake
is
not
blocked.
-
that the exhaust pipe
is
not damaged
and routed so that no
flammable
components
are
touching or in
close
proximity
of
the hot
Parts
of
the
exhaust
system.
-
that the fuel
hoses
are
not
damaged
and that the hose
clamps
are
not
loose.
-
that the
cables are
properly
connec-
ted
and that
the fuse
is
intact.
-
that
the
electrical connections
are
not
conoded.
Test
run
the heater, check
the function, fuel flow and
tempera-
ture.
The
service
should
be carried
out by
a
qualified
service
work
shop.
Y
-9-

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Verwandte Produkte für Ardic 042-D

Inhaltsverzeichnis