Herunterladen Inhalt Inhalt Diese Seite drucken

CashConcepts CCE 112 MULTI Benutzerhandbuch Seite 14

Elektronischer falschgeldprüfer
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Error Management and Servicing
The CCE 112 MULTI checks the genuineness of the banknotes and the valency of the notes by different sensors.
Because the banknotes are led with every test over these sensors, dust and dirt which sticks on the banknotes is
taken up with the time there. Please follow the further following tips to exclude the cleaning of the machine to
avoid mistakes by dirtied sensors and to have an optimum result in the check of banknotes.
Error Message
Error code
E01
E02/E03
E04/E05
E06
E07
E08
E09/E10/E11/E12
E20
Cleaning the Sensors
By the bank notes and by dust it comes to depositions at the sensors of the machine. This pollution lead to
increased non-recognitions of real banknotes.
Please clean at regular intervals the sensors of the CCE 112 MULTI. Switch off the machine and
take out the power supply of the CCE 112 MULTI.
Open the cover with the display upwards. With a soft paintbrush and glasses cleaner you can remove the dust
from the sensors as well as from the banknote tranportation belts.
CashConcepts
CCE 112 MULTI
Error code
P01
P02
P03
P04
P05
P06
P07
P08
P09
P10
Suspected banknote
Suspected banknote
Suspected banknote
Suspected banknote
Wrong input of the
banknote
Suspected banknote
Suspected banknote
Wrong input of the
banknote
Error reason
Upper left IR sensor - defect
Upper right IR sensor - defect
Below left IR sensor - defect
Below right IR sensor - defect
Feeding sensor – defect
Size sensor – defect
Red spectrum failed
Blue spectrum failed
Right passing sensor - defect
Left passing sensor - defect
Error reason
Length error
Magnetic feature error
IR feature error
Thickness error
Slant note
Hologram error
Paper quality error
Passing error
14