4 DEVICE ADVANCE SETTING

4.1

pH setpoint adjustment

7.4
Press the SET button to display the
setpoint value.
4.2

Redox setpoint adjustment

700
Press the SET button to display the
setpoint value.
4.3

Operating principle :

The PICO DUO adjusts its dosage proportionally to demand. In other words, it will dose less if the displayed
measurement is close to the desired pH or Cl setpoint. To dose less, the PICO DUO intersperses increasingly
longer pause times between increasingly shorter running times.
This is why the pump is often stopped, even though the display is not identical to the setpoint.
This is normal.
Adjusting pH or Redox slowly preserves the natural quality of your water.
After 30 minutes without pressing any key, the backlight switches off to save energy. Pressing SET
or CAL briefly switches it back on.
Instruction and user manual PICO DUO Rx controller
To change the setpoint value, hold down the SET
button and press the CAL button in pulses. Each
press changes the value by 0.1 between 7.0 and 7.6.
To change the setpoint value, hold down the SET
button and press the CAL button in pulses. Each
pulse changes the value by 10mV between 350 and
850mV.
15
7.5
750