2.4.5 Electrical connection
Power cable
I
: Plug cable I into the electrical box D present on your pool on the terminals of an auxiliary contact to the
filter pump relay.
The voltage to be applied to this cable is 230V~. This means the unit will only be powered when the filtration
pump is running.
OPTIONAL Connection of suction rods to the unit.
2 protective jack covers
2.4.6 Description of pH and Rx probe assembly
After removing the protective cap from the electrode, insert all parts in the order shown in fig. 9. When all
parts are engaged, screw on the nut without locking it, then gently push the electrode to the bottom of the
pipe and finally raise it about 2 cm so that the tip is in the middle of the pipe. Connect the probe connector
at the rear of the pump to the BNC socket (fig.10).
Instruction and user manual PICO DUO Rx controller
I
Remove the 2 protective covers
from the jack sockets
If you remove the suction rods for an extended period :
replace the protective caps on the jacks
12
D
Plug the jack plug into the
socket