3 START-UP AND OPERATION

3.1

Calibration procedure

This operation is used to specify the measurement of the PICO DUO's pH and Rx sensors.
Before calibrating the probe, remember to :
Stop the filtration pump.
Close any existing isolation valves.
Remove electrode from probe holder.
Fit gasket "D" (fig. 1), then close with the cap to plug the hole
in the probe holder left free by the probe.
Open isolation valves if present.
Switch on the filter pump and check that the PICO DUO is
displaying a pH and ORP value. If it displays "OFF", press the
"ON/OFF" button to switch it on.
Calibrate the probe, then repeat the above steps to replace
the electrode.
Instruction and user manual PICO DUO Rx controller
Insert plug into bayonet
socket
13
Turn plug ¼ turn to close
connection
The hydraulic tube is fitted to the strainer and
pump in the same way.
1 : Slide tube through nut
2: Engage the tube at the bottom of the conical
fitting
3: Hand-tighten nut onto fitting
Fig. 12
Fig. 10
Cap
O-ring seal
Probe holder