2.4.7 Description of tube mounting on injection valve
Nut
Tube
Fitting
Fig. 11
3 START-UP AND OPERATION
3.1
Calibration procedure
This operation is used to specify the measurement of the PICO DUO's pH and Rx sensors.
Before calibrating the probe, remember to :
•
Stop the filtration pump.
•
Close any existing isolation valves.
•
Remove electrode from probe holder.
•
Fit gasket "D" (fig. 1), then close with the cap to plug the hole
in the probe holder left free by the probe.
•
Open isolation valves if present.
•
Switch on the filter pump and check that the PICO DUO is
displaying a pH and ORP value. If it displays "OFF", press the
"ON/OFF" button to switch it on.
•
Calibrate the probe, then repeat the above steps to replace
the electrode.
Instruction and user manual PICO DUO Rx controller
Insert plug into bayonet
socket
13
Turn plug ¼ turn to close
connection
The hydraulic tube is fitted to the strainer and
pump in the same way.
1 : Slide tube through nut
2: Engage the tube at the bottom of the conical
fitting
3: Hand-tighten nut onto fitting
Fig. 12
Fig. 10
Cap
O-ring seal
Probe holder