Herunterladen Diese Seite drucken

Balluff BFB 75K-002 Serie Montageanleitung Seite 3

Faserbasisgerät

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BFB 75K-002 / 003-...
Instructions for use
1.
Push buttons only with finger!
Operating mode
Do not use sharp objects!
Use the buttons
to change the
settings/functions.
Pressing the
Set button either
selects the desired function
2.
Fine adjustment
or
of the switching
saves the desired setting.
point
If the set mode is left without pressing
the
Set button, the previous setting
remains unchanged.
For changing the configuration, press
the
Set button for 3 s.
System is in selection mode and
3.
Teach-in
displays Adjust „ADJ".
switching points
For leaving configuration any time,
press the
Set button for more than
2 s (Exeption: teach point 2).
The settings are saved.
The teach-in function may also be
made via external teach-in ET (see
Technical Data).
Procedure external teach ET
4.
Inversion signal
3 s at +U
define teach point 1
output
B
open
3 s at +U
define teach point 2
B
open
setting saved
end of external teach
For cancelling the keylock (Loc),
press
or
button for at least 15 s.
5.
Sensor precision
It is possible to set on-delay and / or
and speed
off-delay.
functions
Information regarding the setting
of the switching points and swit-
ching frames
When the switching points were set
as frame function, the
button indi-
cates the upper switching point and
the
button the lower one.
As long as the set button is activated
while setting teach or frame point 2,
6.
the teach points are determined dyna-
Timer setting
mically. Thus, moving objects can be
taught-in. The switching point is in the
middle between the lowest and the
highest signal value.
The frame ranges from the lowest to
the hightest signal value.
Factory condition:
Factory setting
Signal output
N.O.
(switching mode):
Precision and speed
Standard (Stnd)
7.
Special functions
functions:
Timer setting:
no timer func-
tions set (off)
Special functions:
no activ
Balluff GmbH
D-73765 Neuhausen/Filder, Tel. 07158 173-0, Fax 07158 5010
Montage- und Bedienungsanleitung / Mounting and operating instructions
Time-lock
CONF
CONF
unlocked
3 sec
Measured value flashes,
correct switching point with
switching point most recently set.
Mode is
activated
Frame point 1
Frame point 2
Mode is
Define teach point
activated
1
Define frame point
1
Cancel
Mode is
Doesn't invert
activated
signal output
Inverts signal
output
Mode is
Standard mode
activated
Fine mode =
highest precision
Fast mode
High distance
mode
Mode is
No timer function
activated
Switch-off delay
Switch-on delay
Set one-shot
delay
Mode is
Reset to factory
activated
state
Reading direction
of display
Lock buttons
CONF
, counter starts with the
ADJ
CONF
Measured value flashes,
correct frame point 1 or 2 with
CONF
frame point most recently set.
CONF
Position
Define teach point
ADJ
object
2
CONF
Position
Define framepoint
ADJ
object
2
CONF
ADJ
CONF
CONF
NC
CONF
FUNC
CONF
Note:
FUNC
FSET modification
requires new
teach-in
CONF
(Pos.3: SP mode)
FUNC
CONF
FUNC
Set the delay times 0, 1,
CONF
CONF
5, 10, 15, 20, 30, 50, 75,
DELAY
100, 150, 200, 300, 500,
CONF
1000, 2000 milliseconds
DELAY
with
CONF
Set the shot times 1, 5,
DELAY
10, 15, 20, 30, 50, 75,
CONF
100, 150, 200, 300, 500,
DELAY
CONF
1000, 2000 milliseconds
DELAY
with
Factory state not
CONF
activated
CONF
Activate Factory
CONF
state
Don't turn
CONF
7-segment display
CONF
Turn 7- segment
CONF
display by 180 °
Don't lock buttons
CONF
CONF
CONF
Lock buttons
LOCK
/
Instructions de service et de montage
CONF
, counter starts with the
ADJ
CONF
CONF
Position
ADJ
ADJ
object
CONF
CONF
Position
ADJ
ADJ
object
CONF
Display off
Display on
CONF
Note:
Menu path depends on
whether a switching point or
frame point is set.
Printed in Germany

Werbung

loading

Diese Anleitung auch für:

Bfb 75k-003 serie