POWER, READER, AND I/O CONNECTION

Input Connection

Door Open Sensor
Exit Button
Door Open Sensor
Exit Button
- Exit Button Connection (Input #1, Input #3)
1.
Connect one line of the Exit button to an input port (Door 1: Input #1, Door 2:
Input #3) of the Exit button.
2.
Connect the other line of the Exit button to GND (-).
- Door Sensor Connection (Input #2, Input #4)
1.
Connect one line (COM) of the door open/close sensor to the input port
(Door 1: Input #2, Door 2: Input #4) of the door sensor.
2.
Connect the other line (NC) of the door sensor to GND (-).
Two Door Control
Three Door Control
Four Door Control
8
_Installation and External Connection
GND
Input #7
GND
Input #6
GND
Input #5
GND
Input #4
GND
Input #3
GND
Input #2
GND
Input #1
Door Number
External Reader
1
Input #1
2
Input #3
1
Input #1
2
Input #8
3
Input #10
1
Input #1
2
Input #3
3
Input #8
4
Input #10
Internal Reader
Note
Input #2
Input #4
Input #2
Input #9
I/O Board
Input #11
I/O Board
Input #2
Input #4
Input #9
I/O Board
Input #11
I/O Board