7. First start-up
Welcome
Model: XXXXX - S/N: XXXXXX - Build: XXXXXXX - FMW:
Start Settings
XXXXX - Version: 5.02
Tap ''Start settings''.
Western
Europe
France
Belgium
Netherlands
Germany
Northern
Southern
Western
Austria
Switzerland
Rest of Europe
Next
Tap your required
Tap your area.
country then ''Next''.
10:35 - 10/12/2021
Set your Time Zone
Select Date
DAY
MONTH
YEAR
DAY
MONTH / DAY / YEAR
• Los Angeles: -8 winter, -7 summer
• New York: -5 winter, -4 summer
/
/
+1
11
11
01
2021
• London: +0 winter, +1 summer
DAY / MONTH / YEAR
• Paris: +1 winter, +2 summer
• Dubai: +4 • Beijing: +8 • Tokyo: +9
• Sydney: +10 winter, +11 summer
Next
Next
Set the date and tap ''Next''.
Set your time zone and tap
''Next''.
For models without display, please use the
app to set your transmitter.
8. Probe connection/disconnection
Connect a probe to the Si-C320 transmitter
b
a
CLICK
Disconnect a probe from the Si-C320 transmitter
a
c
Languages
Skip
English
French
Spanish
Italian
German
Portuguese
Chinese
Next
Select your language
and tap ''Next''.
Select Continent
Africa
Europe
North America
LATAM
Middle East
APAC
Tap your continent.
10:35 - 10/12/2021
Set your time
MINUTES
DAY
MINUTES
24 hours
:
0
+1
:
0
0
AM
PM
Next
Set your time and
tap ''Next''.
10:35 - 10/12/2021
Channel Con guration
Please connect the probe(s)
before con guring the
channel(s)
Next
The transmitter is set. You can
connect a probe to set a channel.
•
Present the probe connector (a)
with its arrow and padlock face
to the transmitter connector (b).
•
Push in the probe connector (a)
into the transmitter connector (b)
until you hear a click. The probe
is correctly connected.
•
Turn the ring (c) of the probe
connector to the left.
•
Pull the probe connector (a)
away from the transmitter
connector (b).
b
9. Set a channel
10:35 - 10/12/2021
10:35 - 10/12/2021
Channel Con guration
Select Channel
Channel 1
Please connect the probe(s)
Channel 2
before con guring the
channel(s)
Channel 3
Channel 4
Next
Next
Connect a probe to set a
The list of available channel is
channel and tap ''Next''.
displayed.
Tap the required channel.
10:35 - 10/12/2021
Select Channel
Channel 1
Channel 2
Channel 3
Channel 4
Next
Next
Channel 2 is con gured. Tap
next to con gure outputs.
For models without display, please use the app to set your channel.
10. Set an output
Activate the channel taping
.
''Measures'', ''Units'', ''Coef cient'' and
''Offset'' are now available.
10:35 - 10/12/2021
10:35 - 10/12/2021
Select Analog Output
Output 2
Output 1
Output type
Output 2
High Range (%RH)
Output 3
Low Range (%RH)
Output 4
Diagnostic
Next
Activate the output taping
Tap the output to set corres-
Set the output type and high
ponding to the previously
and low range values then tap
con gured channel.
the back arrow on the top left.
For models without display, please use the app to set your output.
11. Maintenance
Please avoid any aggressive solvents. Please protect the transmitter and its probes from any cleaning
product containing formalin, that may be used for cleaning rooms or ducts.
Next
12. Precautions for use
Please always use the device in accordance with its intended use and within parameters described in the
user manual in order not to compromise the protection ensured by the device.
10:35 - 10/12/2021
Channel 2
PROBE 1
PROBE 2
MODULE
SELECT UNIT
Measures
Units
- - - -
1.000
Coef cient
0.00
Offset
Tap ''PROBE 1'', ''PROBE
2'' or ''MODULE''.
Parameters to set are now
available.
10:35 - 10/12/2021
Channel 2
PROBE 1
PROBE 2
MODULE
Rel. Humidity
Measures
%RH
Units
1.000
Coef cient
Offset
0.00
Set the parameters according
to your needs then tap the
back arrow on the top left.
10:35 - 10/12/2021
Select Analog Output
10:35 - 10/12/2021
4-20 mA
Output 1
Select Channels
98.0
Output 2
Channel 1
10.0
Output 3
Channel 2
Output 4
Channel 3
Next
Channel 4
.
Tap ''Next'' to
Next
display measures.
10:35 - 10/12/2021
Measures
Channel 2
1
27.7
%RH