Battery Operating Status
Charge Overcurrent
Discharge Overcurrent
Short Circuit
Trigger
Primary
Protection
Recover
Trigger
Secondary
Protection
Recover
Trigger
Ultimate
protection
Recover
Trigger
Primary
Protection
Recover
Trigger
Secondary
Protection
Recover
Trigger
Ultimate
protection
Recover
Trigger
Protection
Recover
EN
— 23 —
Condition (For Reference Only)
Charge Current ≥ 250A (15s)
Discharge Current ≥ 0.5A
or
Recover automatically after 60s
Charge Current ≥ 350A (5s)
Discharge Current ≥ 0.5A
or
Recover automatically after 60s
Charge Current ≥ 480A (200ms)
Discharge Current ≥ 0.5A
or
Recover automatically after 60s
Charging is locked when the Ultimate
Protection is triggered three times.
Discharge Current ≥ 250A (60s)
Charge Current ≥ 0.5A
or
Recover automatically after 60s
Discharge Current ≥ 450A (30s)
Charge Current ≥ 0.5A
or
Recover automatically after 60s
Discharge Current ≥ 480A (200ms)
Charge Current ≥ 0.5A
or
Recover automatically after 10s
Discharging is locked when the Ultimate
Protection is triggered three times.
Discharge Current ≥ 1000A
Discharging is shut down for 10s when
Short Circuit Protection is triggered. For
the threeth time in a row that Short Circuit
Protection is triggered, discharging is
locked.
Charge Current ≥ 0.5A and discharging is
unlocked.