Herunterladen Diese Seite drucken

PROTEC.class PDSU22GDJNS Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für PDSU22GDJNS:
Annual time switch
Jahresschaltuhr
PDSU22GDJNS
05105289
M
230 V 50/60 Hz
~
R 5 a / +25 °C
P
1,5 W
~ 0,1 s/d
16 A/250 V~µ cos ϕ = 1
8 mm
1,5...4 mm
1,5...2,5 mm
2
2
+
-
- 20 °C ... +55 °C
+
-
- 20 °C ... +60 °C
IP
IP 20
!
Safety notes
This product may be installed only by a qualified electrician. Non-compliance may result in a fire hazard or electric shocks.
Before installation, read the operating instructions and observe the product-specific requirements for the installation location. Use only original
spare parts for repair and maintenance. All products may be opened and repaired only by specially trained personnel. Unauthorised opening and
repair by other persons will invalidate all claims for liability, replacement or warranty services.
The device contains a LiMnO
primary cell. When the product reaches the end of its life, this cell must be correctly removed and disposed of in
2
accordance with national legislation and the requirements of environmental protection.
!
Sicherheitshinweise:
Dieses Produkt darf nur durch eine Elektrofachkraft installiert werden, anderenfalls besteht Brandgefahr oder Gefahr eines elektrischen Schlages.
Vor der Installation die Bedienungsanleitung lesen, den produktspezifischen Montageort beachten und nur Originalzubehör benutzen. Alle
Produkte dürfen ausschließlich nur durch geschultes und zugelassenes Personal geöffnet und repariert werden. Durch unbefugte Öffnung oder
Reparatur erlöschen alle Haftungs-, Ersatz- und Gewährleistungsansprüche.
Das Gerät enthält eine LiMnO
Primärzelle. Diese muss nach Produktlebensdauer fachgerecht entnommen und nach den landesspezifischen
2
gesetzlichen Bestimmungen umweltgerecht entsorgt werden.
Operating principle: Typ 1.B. S. T.
IEC/EN 60730-1, IEC/EN 60730-2-7
Operation in a normal environment
Montage: in distribution panel
Degree of contamination: 2
Switch output, potential-free
Rated impulse voltage: 4 kV
The CD supplied contains detailed operating descriptions
ausführliche Funktionsbeschreibungen befinden sich auf der beigefügten CD
PROTEC Produktmanagement
Ludwig-Erhard-Straße 21 - 39
65760 Eschborn
www.protecclass.de
R
c
4000 W
2000 W
600 W 70µF
8 mm
+
+
2000 W
2000 W
2000 W
LED
1000 W
Wirkungsweise Typ 1.B. S. T.
IEC/EN 60730-1, IEC/EN 60730-2-7
Betrieb in üblicher Umgebung,
Montage: Verteilereinbau
Verschmutzungsgrad: 2
Schaltausgang potentialfrei
Bemessungsstossspannung: 4 kV
!
Dangerous electrical voltage in the antennas (230
V to ground pontential).
Before opening the housing the device must absolutely
be disconnected from mains.
!
Gefährliche Netzspannung in den Antennen
(230 V gegen Erdpotential)
Vor dem Öffnen des Gehäuses sind die Geräte unbedingt
freizuschalten!
2000 W
+
1000 W
a Function
b Receptacle for data key
c Select menu, back to main menu, Hold down > 1 s = operating display
d / i Select menu options or set parameters
e Overview of programmed switching times for the week. Resolution 0,5 h
f Switch status
g Day, Time, Date
h Confirm selection or load parameters
 Antenna
 Channel display
!
It should be noted that this device may only used with the antenna type reference 05105409
or 05104725 otherwise there will be danger of electric shock.
• The device should not be used on isolated low voltage.
After applying the supply voltage, the time switch starts automatically with the last
selected function. The relay position is set by the current program.
• Battery backup: Backlighting not active.
• Data key READ/WRITE only via the menu.
a Funktion
b Aufnahme für Datenschlüssel
c Menüauswahl, Zurück im Menue, Betätigung >1 s = Betriebsanzeige
d / i Auswahl der Menüpunkte oder Einstellen der Parameter
e Wochenübersicht der programmierten Schaltzeiten. Auflösung 0,5 h
f Schaltzustand
g Tag, Uhrzeit, Datum
h Bestätigung der Auswahl oder Übernahme der Parameter
 Antenne
Kanalanzeige
!
Das Gerät darf nur mit der Antenne Referenznummer 05105409 oder 05104725 verwendet
werden, ansonsten besteht die Gefahr eines elektrischen Schlages.
• Das Gerät darf keine SELV schalten.
Nach Anlegen der Netzspannung startet die Uhr mit der zuletzt eingestellten Funktion.
Die Relaisstellung wird durch das aktuelle Programm vorgegeben.
• Gangreserve: Hintergrundbeleuchtung nicht aktiv.
• Datenschlüssel LESEN/SCHREIBEN nur über das Menü.
max. 250 V AC
Supply voltage
230 V
check polarity
Polung prüfen
max. 50 m
max. 250 V AC L
max 16 A
L
N
L
N
e
0
6
12
16
24
f
a
g
b
h
c
i
+ -
d
max 16 A
N
05105409
05104725
Antenna DCF77
Antenna GPS
must be ordered separately
Antenne DCF77
Antenne GPS
bitte separat bestellen
loading

Inhaltszusammenfassung für PROTEC.class PDSU22GDJNS

  • Seite 1 • Annual time switch • Jahresschaltuhr PDSU22GDJNS max 16 A PROTEC Produktmanagement Ludwig-Erhard-Straße 21 - 39 max. 250 V AC 65760 Eschborn 05105289 Dangerous electrical voltage in the antennas (230 www.protecclass.de V to ground pontential). Supply voltage Before opening the housing the device must absolutely be disconnected from mains.
  • Seite 2  • Select • Overview COUNTRY, adjust LONGITUDE / LATIDUDE • LAND auswählen, einstellen von LÄNGE und BREITE • Übersicht      Select country. Select the city closest to the planned location for use. Land auswählen.  Stadt auswählen, die dem Einsatzort am nächsten gelegen ist.
  • Seite 3  ON at sunset PROGRAM / WEEK PROGRAMM / WOCHE • • Einschalten bei Sonnenuntergang This menu item is provided for the simple input of programs which are to be repeated weekly (such as switching of lights and boilers). A weekly program consists of an ON time, an OFF time and the associated ON and OFF days. OFF at sunrise •...

Diese Anleitung auch für:

05105289