INDICE
10.5 Maintenance every 2 years
10.5.1 Oil change
Proceed as follows to change oil in the tank:
-
Turn the main switch (1) to the unit off position "O".
-
Remove the guard (2) by means of the fastening devices (3).
-
Remove the plug (4).
-
Remove spent oil from the tank (5).
-
Fill the tank (5) with new oil.
-
Close the plug (4).
-
Vent air from the hydraulic system (see the "Hydraulic circuit air venting procedure" paragraph).
-
Check the oil level.
-
Assemble the guard (2) by means of the fastening devices (3).
-
At the end of operations, clean any residues.
-
Properly dispose of spent oil.
Always use oil with the same chemical characteristics. It is prohibited to use different types
of oil, even just to top-up.
O
I
4
5
1
2
CAUTION
0529-M001-0
3
3
3
3
145