RISE 2000 DIRECT CONTROL Motorized Display Lift Floor-Wall Solution Installation & User Manual CONTENTS Product manual Important Safety Information Produkthandbuch Declaration of Conformity Manuel de produit Mounting Instructions Producthandleiding User Instructions Product Data Sheet Checklist Contact Details...
R R I I S S E E 2000 DIRECT CONTROL Important Safety Information - GB Important safety information for both Electrical Safety Mechanical safety installer and user Connect unit to a properly grounded outlet Assure installation of unit by authorized Installer: Before starting the installation only.
Seite 4
R R I I S S E E 2000 DIRECT CONTROL Belangrijke veiligheidsinformatie - NL Belangrijke veiligheidsinformatie voor zowel Elektrische veiligheid Mechanische veiligheid installateur als gebruiker Sluit het apparaat alleen aan op een Laat de installatie van het toestel uitsluitend Installateur: Lees aandachtig de veiligheids- correct geaard stopcontact.
Seite 5
R R I I S S E E 2000 DIRECT CONTROL Wichtige Sicherheitshinweise – DE Wichtige Sicherheitshinweise für Monteure und Elektrische Sicherheit Mechanische Sicherheit Verbraucher Schließen Sie das Gerät nur an eine Stellen Sie sicher, dass das Gerät nur von einer Monteure: Bitte lesen Sie die Sicherheitshinweise, ordnungsgemäß...
Seite 6
R R I I S S E E 2000 DIRECT CONTROL Informations importantes concernant la sécurité - FR Informations importantes concernant la Sécurité électrique Sécurité mécanique sécurité de l’installateur et de l’utilisateur Ne branchez l’appareil que sur une prise de Veillez à...
Seite 7
R R I I S S E E 2000 DIRECT CONTROL Información importante de seguridad - ES Información de seguridad importante tanto Seguridad eléctrica Seguridad mecánica para el instalador como para el usuario Conecte la unidad únicamente a una toma Asegúrese de que la instalación de la Instalador: Antes de comenzar la instalación, de corriente con conexión de puesta a...
Seite 8
R R I I S S E E 2000 DIRECT CONTROL Importanti informazioni sulla sicurezza - IT Importanti informazioni sulla sicurezza per Sicurezza elettrica Sicurezza meccanica l’installatore e per l’utente Collegare l’unità esclusivamente a una Assicurarsi che l’installazione dell’unità sia Installatore: Prima di iniziaare l’installazione presa adeguatamente messa a terra.
Seite 9
R R I I S S E E 2000 DIRECT CONTROL Ważne informacje dotyczące bezpieczeństwa - PL Ważne informacje dotyczące bezpieczeństwa Bezpieczeństwo elektryczne Bezpieczeństwo mechaniczne dla instalatora i użytkownika produktu Urządzenie należy podłączać wyłącznie do Montaż urządzenia może być przeprowadzony Instalator: przed rozpoczęciem instalacji prawidłowo uziemionego gniazdka.
Seite 10
R R I I S S E E 2000 DIRECT CONTROL Важная информация по технике безопасности - RU Важная информация по технике безопасности Электробезопасность Механическая безопасность для монтажной организации и пользователя Подключайте устройство только к правильно Монтажом устройства должен заниматься Монтажная...
RISE 2000 DIRECT CONTROL Additional Safety Information ADDITIONAL SAFETY INFORMATION Power rating: Technical guideline The lifting system is equipped with an Y-cable. The first lead of the Y-cable is used for the internal power supply of the lift system (400W). The installer has the possibility to connect a display and other peripherals of max 900W to the other lead of the Y-cable.
RISE 2000 DIRECT CONTROL Declaration of Conformity...
Seite 13
RISE 2000 DIRECT CONTROL Mounting Instructions 4X 8,4X25X30 4X M8X45 4X M8X20 4X M8X14 4X M6X18 4X M6X12 8X M6x12x1,6 8X M8x16x1,6 WARNING...
Seite 14
RISE 2000 DIRECT CONTROL Mounting Instructions MAX POWER (WATT) = 400W MAX POWER OFF DISPLAY EXTRA DEVICES = MAX 900W F R O N BACK...
Seite 15
RISE 2000 DIRECT CONTROL Mounting Instructions UNTIE PULL LOSBINDEN ZIEHEN B A C B A C TYRAP TYRAP INCLUDED...
Seite 16
RISE 2000 DIRECT CONTROL Mounting Instructions F R O N OPTION 2 OPTION 1...
Seite 17
RISE 2000 DIRECT CONTROL Mounting Instructions LOOSEN 2x B A C 3 Nm F R O N FIX 2x B A C 3 Nm...
Seite 18
RISE 2000 DIRECT CONTROL Mounting Instructions OPTIONAL: REQUIRED FOR RISE WBS65, WBS75 AND WBS86 (CHECK MANUAL WHITEBOARD SETS) 550 mm FIX 8X (5.5-6 TURNS) 13 mm FIX 2x 18 Nm B A C 3 Nm...
Seite 19
RISE 2000 DIRECT CONTROL Mounting Instructions MAX 5 CABLES (ø7mm) B A C 275 mm 275 mm...
Seite 20
RISE 2000 DIRECT CONTROL Mounting Instructions (2x) H2.5 WARNING: THE LIFT DOES NOT FUNCTION IF THE GYRO IS NOT MOUNTED CORRECTLY. MAKE SURE THE GYRO IS MOUNTED FIRMLY TO THE COLUMN AND INSERT THE CONNECTOR INTO THE CONTROL BOX. ACHTUNG: DER LIFT FUNKTIONIERT NICHT, WENN DER GYRO NICHT RICHTIG MONTIERT IST.
Seite 22
RISE 2000 DIRECT CONTROL Mounting Instructions OPTIONAL: REQUIRED FOR RISE WBS65, WBS75 AND WBS86 (CHECK MANUAL WHITEBOARD SETS) 4X 8,4X25X30 4X M8X45 4X M8X20 4X M8X14 4X M6X18 4X M6X12 8X M6x12x1,6 8X M8x16x1,6 VESA 300x300 - VESA 800x600 OPTIONAL...
Seite 23
RISE 2000 DIRECT CONTROL Mounting Instructions...
Seite 24
RISE 2000 DIRECT CONTROL Mounting Instructions FIX TIGHT (L+R) POWER ON CALIBRATING = ORANGE READY = GREEN ERROR = RED DO NOT PUT WEIGHT ON THE SY EM SY EM CALIBRATES THE WEIGHT CALIBRATING IS READY ERROR (TRY RESET)
Seite 25
RISE 2000 DIRECT CONTROL Mounting Instructions OPERATION BY MANUALLY PRESS DOWN APPLYING PRESSURE PUSH...
RISE 2000 DIRECT CONTROL User Instructions MAXIMUM LOAD OF THE LIFT IS 140 KG / 308 LBS. MAXIMUM WEIGHT OF THE DISPLAY IS 100 KG / 220 LBS. MAXIMALE BELASTUNG FÜR DIESEN LIFT IST 140 KG / 308 LBS. MAXIMALE GEWICHT DES BILDSCHIRMS IST 100 KG / 220 LBS. DE Achtung! Risiko des Zerquetschens DK Forsigtig! Fare for knusning ES ¡Precaución! Peligro de apla amiento...
RISE 2000 DIRECT CONTROL User Instructions OPERATING FUNCTIONALITY RISE FUNCTION REQUIRED ACTION Going up PUSH DISPLAY Going down PULL DISPLAY DOWN Reset system 1. Move system to lowest position (if possible). If not, start with point 2. 2. Pull display down and hold at least 10 seconds, indicator LED will become red. 3.
Note: This document and specifications herein are confidential and the exclusive property of Vogel's Products b.v. Neither this design nor any information T510279 01 contained in this drawing may be reproduced or disclosed to others without written consent of Vogel's Products b.v. The design and information will not be Product data sheet reproduced, copied or used, either in part or in its entirety, as the basis for the manufacture or sale of items without written permission.
RISE 2000 DIRECT CONTROL Checklist CHECKLIST RISE 2000 DIRECT CONROL MOTORIZED DISPLAY LIFT FLOOR-WALL SOLUTION: Check whether the interface strips have been secured to the interface bar by fixing the screws from the bottom. Check whether maximum weight of the display (max. 100kg) and lift + peripherals (max. 140 kg) is not exeeded.
Vogel’s Products BV HONDSRUGLAAN 93, 5628 DB EINDHOVEN, THE NETHERLANDS T +31 (0)40 264 74 00 E info@vogels.com W www.vogels.com (GB) Subject to printing errors and technical amendments. (NL) Drukfouten en technische wijzigingen voorbehouden. Sous réserve de fautes d’impression et de modifications techniques. Für Druckfehler übernehmen wir keine Verantwortung.