Herunterladen Diese Seite drucken

VEVOR SCA-60W Bedienungsanleitung Seite 8

Saunaofen
Vorschau ausblenden Andere Handbücher für SCA-60W:

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 33
Model
SCA-60W
SCA-80W
SCA-90W
Above suggested heating time should be achieved, including but not
limited to these:
1. Room thermometer installed opposite to the sauna heater, closing to
the ceiling.
2. Sauna room is installed indoor with insulation for diffusion prevention
purpose.
3. Temp knob adjust to the Max.
INSTALLATION OF TEMPERATURE SENSOR
1.Fasten the sensor unit with screws to the wall straight over sauna heater
inside the sauna room. Check diagram for minimum distance (See fig3).
2. Wire from sensor unit connect to the Power circuit of control panel.
(Item 1: Sauna heater inside the sauna room, Item 2: Sauna control panel
outside the sauna room, Item 3: Temperature sensor unit inside the
sauna room)
Power
(kW)
Min
6.2
8
9
Sauna room
Volume(m³)
Max
5
9
8
12
9
13
- 7 -
Suggestion heating time
(28-70℃)
30-50min
30-50min
30-50min

Werbung

loading

Diese Anleitung auch für:

Sca-80wSca-90w