Herunterladen Diese Seite drucken

AutoAqua Smart AWC touch Bedienungsanleitung Seite 8

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

English
Calculating the Water Change Volume
The volume can be calculated by multiplying the width and length of your
tank and the distance between the pyramids of the two sensors. *
For example, a tank is 18 inches in length and 17 inches in width. If the
distance between the two sensors is 3 inches, the water change volume is
approximately 4 gallons.
18" (L) X 17" (W) X 3" (H) = 918 cubic inches (around 4 gallons)**
* The water volume might be in uenced by factors such as the speed of return pump.
Slower re lling speed could reduce the variation. Please refer to the 3rd part of
Programming section.
**231 cubic inch = 1 US gallon
Width : 17"
Auto Water Change Process
1. Old water in the tank/sump is pumped out until the water
level reaches S2.
2. There is a 3-minute pause before re lling new water.
3. New water is re lled into the tank/sump until the water level
reaches S1.
*Users can skip the pause by touching
07
Water Change Volume
Length : 18"
.
Height : 3"
*

Werbung

loading

Diese Anleitung auch für:

Sawc-200p